CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
Cable and Pin Information
Cabling Recommendations
The tables in this section contain the maximum supported lobe lengths. The
maximum lengths reflect the longest lengths supported by the transmission
characteristics of IEEE 802.5-compliant adapters. The recommended distances for
the various cable types are set by North American and international commercial
building wiring standards. These standards state that standards-compliant
horizontal copper cabling shall not exceed 90 m (295 ft) leaving 10 m (33 ft) total
for required patch cabling in both the office and telecommunications closet. It is
good practice to follow the cabling standards guidelines when installing building
cabling to help ensure a longer useful life for your cabling infrastructure, migration
to new technologies, and maximum flexibility for the network configuration.
If you are installing new cabling for data applications, it is recommended that you
use the following types of cable:
Cable Type
Impedance
Types 1 and 1A
150 Ohm
Types 2 and 2A
150 Ohm
Type 8
150 Ohm
Type 9
150 Ohm
Type 3
100 Ohm
Category 3
100 and 120 Ohm
Category 4
100 and 120 Ohm
Category 5
100 and 120 Ohm
Table 26. Copper Cable Types
Cable Type
65.5 Micron Fiber
50/125 Micron Fiber
100/140 Micron Fiber
Table 27. Multimode Optical Fiber Cable Types
Summary of Contents for CrossFire 8600
Page 1: ...DOC 6951 1 2 CrossFire TM 8600 8605 Guide to Operations Token Ring Switches...
Page 2: ......
Page 3: ...CrossFire TM 8600 8605 Token Ring Switches Guide to Operations...
Page 6: ...iv CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641...
Page 32: ...16 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Overview and Specifications...
Page 58: ...42 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Theory of Operation...
Page 160: ...144 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Configuration...
Page 216: ...200 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Troubleshooting...
Page 226: ...210 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Abbreviations...
Page 236: ...220 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Cable and Pin Information...
Page 249: ......