CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
Switch Configuration
Spanning Tree for TrBRF Screen
When you select Spanning Tree from the Configuration menu, a list containing
available TrBRF VLANs appears. Choose a TrBRF to view or edit from the list
before continuing. When you have selected a TrBRF, TrCRFs and ports associated
with the BRF may be selected for modification.
STP Participation
Whether this TrBRF participates in the spanning tree protocol and, if so, the
protocol to be used. Possible values are No, IEEE, IBM, and Base on Bridging
Mode. The default is No.
•
If STP Participation is set to No, then all TrCRFs with this TrBRF as a parent
will be set to forwarding mode. You can then override this by blocking a
particular TrCRF.
•
If STP Participation is set to IEEE or IBM, then the selected protocol will be
used to determine the forwarding/blocked mode of the TrCRFs that are
configured with an STP mode of auto.
•
If STP Participation is set to Base on Bridging Mode, then the spanning tree
protocol used is based on the bridging mode of the TrCRF. If the bridging
mode is SRB, the IBM Spanning Tree Protocol is used. If the bridging mode
is SRT, the IEEE 802.1D Spanning Tree Protocol is used.
For a particular TrCRF the protocols selected here can be overridden. See the STP
Mode parameter in the section “Spanning Tree for TrCRF Screen” on page 101.
Summary of Contents for CrossFire 8600
Page 1: ...DOC 6951 1 2 CrossFire TM 8600 8605 Guide to Operations Token Ring Switches...
Page 2: ......
Page 3: ...CrossFire TM 8600 8605 Token Ring Switches Guide to Operations...
Page 6: ...iv CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641...
Page 32: ...16 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Overview and Specifications...
Page 58: ...42 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Theory of Operation...
Page 160: ...144 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Configuration...
Page 216: ...200 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Troubleshooting...
Page 226: ...210 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Abbreviations...
Page 236: ...220 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Cable and Pin Information...
Page 249: ......