131
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
Switch Configuration
Serial Link Configuration Screen
Use the Serial Link Configuration screen to configure a switch when using a
modem to create a console session.
Hardware Flow Control
Enables or disables RTS/CTS handshaking.
Default: Disabled
Software Flow Control
Enables the XON and XOFF characters, which are 11 and 13 hexadecimal, respectively.
Default: Disabled
Autobaud Upon Break
Indicates whether the baud rate is reset when a Break key sequence (pressing
ENTER
rapidly for five seconds) is sent or received. The default is Disabled. When
set to enabled, a baud rate change can be accomplished by changing the baud rate
of the terminal emulator, disconnecting and reconnecting the TIA/EIA-232 cable,
and then pressing
ENTER
until a screen appears.
Console Baud Rate
The baud rate of the TIA/EIA-232 port. Acceptable baud rates for the console are
1200, 2400, 4800, 9600, 19200, 38400, 57600, or Autobaud. The default value for
this parameter is 9600. Make sure that your terminal emulator baud rate matches
the console baud rate you set.
Summary of Contents for CrossFire 8600
Page 1: ...DOC 6951 1 2 CrossFire TM 8600 8605 Guide to Operations Token Ring Switches...
Page 2: ......
Page 3: ...CrossFire TM 8600 8605 Token Ring Switches Guide to Operations...
Page 6: ...iv CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641...
Page 32: ...16 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Overview and Specifications...
Page 58: ...42 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Theory of Operation...
Page 160: ...144 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Configuration...
Page 216: ...200 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Troubleshooting...
Page 226: ...210 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Abbreviations...
Page 236: ...220 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Cable and Pin Information...
Page 249: ......