1 – 53
Chapter 1 Troubleshooting
FIP1.32 INTERLOCK S/W 24V
Step Check
Yes
No
Possible causes:
INTERLOCK S/W 24V (PL8.1.11)
LVPS (PL12.1.5)
HVPS/MCU (PL12.1.19)
1
Checking INTERLOCK S/W 24V
Disconnect P/J45 from LVPS.
Is P/J45-1 and P/J45-3 continuous, when INTERLOCK
S/W 24V is pushed, and not when released?
Go to FIP1.24
LVPS.
Replace INTER-
LOCK S/W 24V.
(RRP8.5)