www.okinternational.com
- 5 -
P/N 7000-1370, Revision B
Basic Specifications of the APR-5000
APR-5000
Rework System
Base Unit Input Voltage
115VAC/230VAC, 50/60Hz
Base Unit Power
Consumption
2000 watts
Circuit Breaker Subzone
Heaters
15 amp
Circuit Breaker Main Unit
15 amp
Max Source Temperature
Bottom-side heater:
350°C (662°F)
Max Source Temperature
from Micro Oven
400°C (752°F)
Temperature Control/Range Closed-loop
RTD
Maximum PCB Dimensions
250 X 230mm
(10” X 9”)
PCB Thickness
0.5 – 2.0mm
Component Maximum
Weight
55 gm (.92 oz)
Component Types
BGA, CSP, LGA, Micro SMD, MLF
Bumped Chip
Airflow
8-24 l/min
L=8lpm, M=16lpm, H=24lpm
Heater Element
350 W top / 1.5kW bottom
Vacuum Pump
15" Hg 381mm Hg
Base Unit Dimensions
50 X 76 X 71 cm (w X d X h)
Base Unit Weight
64 Kg (140Lbs)
Warranty
One year parts & labor
90 days heaters & lamps
System Part Numbers
Part Number
Item Description
APR-5000
115/230 VAC Array Package Rework
System
APR-5000-COMP
Array Package Rework System with
Computer
APR-5000-COMP-F
Array Package Rework System with
Computer and Flat Screen Monitor
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com