www.okinternational.com
- 30 -
P/N 7000-1370, Revision B
APR-5000 Optical Calibration Procedure
This procedure must be done after the Camera to head Alignment procedure has been
finalized.
Tools Required
Large Vacuum
Gun Sight Tool
Allen Keys
Procedure
1. Turn APR-5000 unit on and boot the APR-5000 Software.
2 Open System Set-Up by clicking System Set-Up.
3. Click on “No Password” button and enter the APR password 94025.
4. Open Calibration Screen and Click on Calibration Tab and then, click the Optical
option.
Click Here for
System Set Up
Option
Type in 94025