EN-48 7000 Series Indicators
1 SECOND
±
2 SECONDS
±
3 SECONDS
±
4 SECONDS
±
mMOdE
PERCENT
mMOdE
DYNAMIC
*
0
0.000
kg
ENTER REF
PErCNt
%
CLEAR REF?
*
0
0.000
kg
PLACE REF OR
100.0
%
12.345 KG
*
0
12.345
kg
PLACE REF OR
12.345
kg
ENTER REF
*
0
0.000
kg
READY
±
*
12.345
kg
5 SECONDS
±
*
12.345
kg
HOLD
±
4.9.3
Percent Weighing
Use this mode to compare the weight of items as a percentage of a Reference Weight.
Defining the Reference Weight
When the
Mode
button is released, CLEAR REF? is displayed. Press the
No
button to use the stored
Reference Weight or press the
Yes
button to establish a new Reference Weight.
When establishing a new Reference Weight., the display alternates between PLACE REF OR and
ENTER REF.
To establish the Reference Weight using an item, place the item on the scale and press the
FUNCTION
button.
To establish the Reference Weight using a numeric value, enter the value using the keypad, then
press the
FUNCTION
button.
Percent Weighing
After defining the reference weight, place an item on the scale and read the value on the display.
The percent value is displayed on the top line and the actual weight is displayed on the bottom line.
NOTE:
Press the
FUNCTION
button to briefly display the Reference Weight.
4.9.4
Dynamic Weighing
Use this mode to weigh moving items or large items that block the display.
NOTE:
If Accumulate is set to MANUAL or AUTO, the in the Setup menu, the held weight is
automatically added to the accumulation data.
Manual operation
(DYNAMIC is set to MANUAL in the MODE menu)
When the display shows READY, place the item on the scale.
Press the
FUNCTION
button to average the readings for the time period defined in the LEVEL setting
(Section 3.6.6).
When averaging is completed, the dynamic icon flashes. The averaged weight and HOLD are
displayed until the
FUNCTION
button is pressed again.
Semi-automatic operation
(DYNAMIC is set to SEMI in the MODE menu)
When the display shows READY, place the item on the scale. The readings are automatically averaged for the time period defined
in the LEVEL setting. The averaged weight and HOLD are displayed until the item is removed and the
FUNCTION
button is
pressed.
Automatic operation
(DYNAMIC is set to AUTOMATIC in the MODE menu)
When the display shows READY, place the item on the scale. The readings are automatically averaged for the time period defined
in the LEVEL setting. The averaged weight and HOLD are displayed until the item has been removed from the scale for 10
seconds.
Summary of Contents for T71P
Page 1: ...7000 Series Indicators Instruction Manual T71P T71XW ...
Page 2: ......