Effective 11/2010
27
Start-up
Once the system has been installed in accordance with the set-up and installation
instructions, it may be energized and cylinder filling may begin. It is highly
recommended that the user read the
„
Touch Screen Overview
‟
section (
Pages 30-43
)
prior to operating the system.
On the
MAIN MENU
screen, press the
CONTROL
button.
Choose between
AUTOMATIC
and
MANUAL
modes of operation. For a detailed
explanation of modes and all other touch screen functions, see the
„
Touch Screen Overview
‟
section (
Pages 30-43
). If selected, the
AUTOMATIC
mode will initialize the system when
pre-programmed conditions are satisfied and the
ON/OFF
button is in the
ON
position.
The
MANUAL
mode requires the user to press an additional
START
button to initialize the
system. This is intended to prevent an inadvertent system initialization. With the system
running, ensure that the air compressor indicator toggles from red to green. The oxygen
booster compressor should toggle from red to green after the oxygen compressor is activated
and that will occur when the system has produced oxygen of
90%
purity or greater for
4
minutes. The system should continue to operate until the desired pressure is reached, a fault
is encountered or it is de-energized by the user.
Shut-down
The
MOGS-100
unit has been programmed to automatically de-energize when cylinder
pressure reaches the set point (normally
2200 psi
i.e.
152 bar
), indicating that cylinder filling
is complete.
The machine may be manually de-energized by pressing the
Power
button on the
CONTROL
screen to
OFF
at any time.
The machine can also be de-energized at any time by pressing the red
Emergency-Stop
button on the front of the control panel. Pressing this button only breaks the electrical power
to the machine. There may still be oxygen stored at high pressure inside the system which
could represent a hazard in an emergency situation.