MPPT PRO-X 10A | 20A | 30A | 40A
— 6 —
3.2.
PV Array Requirements
3.2.1.
Serial connection (string) of PV modules
As the core component of the solar system, the controller could be suitable for various types of PV
modules and maximize converting solar energy into electrical energy. According to the open-circuit
voltage (VOC) and the maximum power point voltage (VMpp) of the MPPT controller, the series
number of different types of PV modules can be calculated. The below table is for reference only.
MPPT PRO-X 10A and 20A:
System
voltage
36 cell
VOC
<
23V
48 cell
VOC
<
31V
54 cell
VOC
<34V
60 cell
VOC
<38
V
max.
best
max.
best
max.
best
max.
best
12V
4
2
2
1
2
1
2
1
24V
4
3
2
2
2
2
2
2
System
voltage
72 cell
VOC
<46
V
96 cell
VOC
<62
V
VOC
>80V
max.
best
max.
best
12V
2
1
1
1
1
24V
2
1
1
1
1
NOTE:
The above parameter values are calculated under standard test conditions
(STC / Standard Test Condition: Irradiance 1000W/m2, Module Temperature 25
℃
, Air Mass1.5.)
MPPT PRO-X 30A and 40A:
System
voltage
36 cell
VOC
<
23V
48 cell
VOC
<
31V
54 cell
VOC
<34V
60 cell
VOC
<38
V
max.
best
max.
best
max.
best
max.
best
12V
4
2
2
1
2
1
2
1
24V
6
3
4
2
4
2
3
2
48V
6
5
4
3
4
3
3
3
System
voltage
72 cell
VOC
<46
V
96 cell
VOC
<62
V
VOC
>80V
max.
best
max.
best
12V
2
1
1
1
1
24V
3
2
2
1
1
48V
3
2
2
2
1
NOTE:
The above parameter values are calculated under standard test conditions
(STC / Standard Test Condition: Irradiance 1000W/m2, Module Temperature 25
℃
, Air Mass1.5.)