Step 4:
Connecting the accessories
Connect the remote temperature sensor cable.
Temperature Sensor
(included)
Remote Temperature Sensor Cable
(Optional)
(Articel: 1-02-010930)
Connect the remote temperature sensor cable to the interface
①
and place the other end close to
the battery.
CAUTION
Suppose the remote temperature sensor is not connected to the controller. In
that case, the default battery charging or discharging temperature setting is
25
°
C without temperature compensation.
Connect the accessories for RS485 communication
Refer to chapter 5 “
Parameters Setting
”
Step 5:
Powering on the controller
Connect the battery fast-acting fuse to power the controller. Then check the battery indicator's status
(the controller operates normally when the indicator is lit in green). Connect the fast-acting fuse and
circuit breaker of the load and PV array. Then the system will be operating in preprogrammed mode.
CAUTION
If the controller is not operating properly or the battery indicator on the controller
shows an abnormality, please refer to 6.2 “
Troubleshooting
”