MPPT PRO-X 10A | 20A | 30A | 40A
— 22 —
Lithium Battery voltage parameters
Battery type
Battery
parameters
LFP
LFP4S
LFP8S
LFP15S
LFP16S
USER
①
over voltage disconnect
voltage
14.8V
29.6 V
55.5V
59.2V
9~17V
charging limit voltage
14.6 V
29.2 V
54.7V
58.4V
9~17V
over voltage reconnect
voltage
14.6 V
29.2 V
54.7V
58.4V
9~17V
equalize charging voltage
14.5 V
29 .0 V
54.3V
58.0V
9~17V
boost charging voltage
14.5 V
29.0 V
54.3V
58.0V
9~17V
float charging voltage
13.8 V
27.6 V
51.7V
55.2V
9~17V
boost reconnect charging
voltage
13.2 V
26.4 V
49.5V
52.8V
9~17V
low voltage reconnect
voltage
12.8 V
25.6 V
48.0V
51.2V
9~17V
under voltage warning
reconnect voltage
12.2 V
24.4 V
45.7V
48.8V
9~17V
under voltage warning
voltage
12.0 V
24.0 V
45.0V
48.0V
9~17V
low voltage disconnect
voltage
11.1 V
22.2 V
41.6V
44.4V
9~17V
discharging limit voltage
11.0 V
22.0 V
41.2V
44.0V
9~17V
①
The battery parameters under the “USER” battery type are 9-17V for LFP4S. They should be
x2 for LFP8S and x4 for LFP15S/LFP16S.