OETIKER ELK 02 V2.X
9
Menu navigation in the ELK 02
Issue 05.2021
08903352
9-93
Dual closure
Function
Dual closure is an improved type of gap priority closure
The closure starts with force priority until a configurable
changeover force (UK) is reached, when the closure
switches from force priority to gap priority.
The changeover force (UK) must be up to approx. 10 %
less than the force required to achieve the closing gap
(SS).
The value set for the closing force (SK) limits the actual
closing force value during closure.
The value set for the closing force (SK) should be at least
30 % greater than the anticipated value of the closing
force (SK), so as to obtain sufficient control freedom.
Depending on the closure data, the pincer jaws are
opened (OF), opening gap (OS) with and without
verification.
Fig. 60
Summary of Contents for ELK 02 Series