OETIKER ELK 02 V2.X
8
Structure of the PC program
Issue 05.2021
08903352
8-60
System settings for the NO signal
This menu defines the response of the NO output signal at the X2 NO and X20 NO interfaces.
Fig. 40
System settings for the NO signal
Input box/checkbox
Description
One impulse when closure
starts
One pulse is supplied when closure starts.
Factory setting 500 ms (range 10 to 1000 ms)
After each NO
•
continuous signal
Continuous signal until the next start.
If the OS defined at the start time is reached within its tolerance OS-T on
opening the pincer jaws (from SS/SK/VW to fully open), a continuous signal is
output until the next start (factory setting).
NOTICE
: The opening gap (OS) is approached again only after the
acknowledgement time has elapsed.
Summary of Contents for ELK 02 Series