OETIKER ELK 02 V2.X
13
Troubleshooting
Issue 05.2021
08903352
13-130
14 Troubleshooting
14.1 General notes on faults
•
If the closure operation will not start or faults occur during operation, consult the maintenance personnel
responsible for the ELK 02.
•
Operators must inform their supervisor. Under no circumstances should you try to rectify faults on the
ELK 02 yourself. If a fault occurs, please contact OETIKER (www.oetiker.com).
14.2 What to do, when...?
Type of fault
Reason for fault
Actions to rectify fault
Closure operation will not start
Unit not switched on
Switch on unit, execute pincer test
Unit switched on, no display
Control unit fault
Send to OETIKER
Loud noise of rushing air in the
control unit
Leaking valves
Send to OETIKER
Display shows incoherent text
Electromagnetic interference above
permitted limit
Reload all data
Table 44
Fault table
14.3 Error messages and error correction measures
Error
Cause/Error correction
Output X2
Output X20
F01 SUPPLY PRESSURE
Increase supply pressure
NO
à
H
System error
à
H
F02 NO PINCER
Close the pincer
Measuring system defective
NO
à
H
System error
à
H
F03 MEASURING
SYSTEM
Tighten connector screws
Pincer defective
NO
à
H
System error
à
H
F04 OS - ERROR
Modify OS and OS-T
Recalibrate pincer
Replace pincer
NO
à
H
NO
à
H
F05 SK - ERROR
Increase supply pressure
Modify SK and SK-T
Modify SK-HZ
Recalibrate pincer
Replace electronics
NO
à
H
NO
à
H