OETIKER ELK 02 V2.X
9
Menu navigation in the ELK 02
Issue 05.2021
08903352
9-82
Force test
The force test checks the calibration of the closing force at the pincer jaws between the pre-set value in the ELK 02
and the measuring devices.
If 20 closures in force test are exceeded the message “F25 MAX. 20 CLOSURES” appears on the ELK 02 display.
When the message is acknowledged, a mandatory pincer test is required again.
INFO
This monitoring prevents the operation of the ELK 02 in pincer test mode.
Fig. 54
Sequence of operations in the force test
External interface X2/X20 can be selected via the “System settings” – “Other” menu
1)
–
X2: Start/Acknowledge (pulse)
–
X20: Enable and Start (pulse)
2)
–
X2: Start / Acknowledge 4 s
–
X20: Function 4 s
3)
–
X2: Start / Acknowledge 2 s
–
X20: Function 2 s
Summary of Contents for ELK 02 Series