OETIKER ELK 02 V2.X
8
Structure of the PC program
Issue 05.2021
08903352
8-56
Input box/checkbox
Description
After end of system test:
•
continuous signal
•
one pulse
•
no output
When the ELK 02 is powered up the control unit checks its function (system test)
The output can be supplied as
•
continuous signal
•
one pulse (10-1000 ms)
•
no output
Read for closure
•
continuous signal
•
one pulse
•
no output
•
When “Current APN” appears on the ELK 02 display or
•
After a closure and display of the following messages on the ELK 02
display, the ELK 02 is ready for closure:
–
SS + SK OK or
–
SS + SK OK toggling to VW + VK.
The output can be supplied as
•
continuous signal
•
one pulse (10-1000 ms)
•
no output
NOTICE: If the X20 interface is activated (there is an option to switch between
the X2 and X20 interface in the “Other” system settings), a separate output is
available for each of the following statuses:
•
BUSY (during the system test)
•
read for closure
One impulse when closure
starts
One pulse is supplied when closure starts.
Factory setting 500 ms (range 10 to 1000 ms)