69
Step 2. Shared memory setting (PLS/PWM frequency setting)
●
Configure frequency of output pulses after PLS/PWM setting of
shared memory.
●
Frequency is set within the range of 1 Hz to 30 kHz by 1 Hz unit.
Output turns OFF (pulse stop) when frequency setting exceeds
32.768 kHz.
●
When frequency is set to 0 Hz and data is refreshed, pulse output is
stopped.
Step 3. Shared memory setting (PWM duty setting)
●
Configure Duty of output pulses after PLS/PWM setting of shared
memory.
●
Within range of 0% to 100%, by 1% unit. The value indicates the
proportion of ON.
●
0% means output OFF, and 100% means output ON.
Output OFF when value exceeds 101%.
Make sure to access shared memory by 2 word unit
ATTENTION
See
"Shared Memory Areas" in Appendix A
for shared memory addresses.
NOTE
PLS: K1 to K30000
PLS: K1 to K30000
PLS: K1 to K30000
PLS: K1 to K30000
Address: 148h 149h
Address: 14Ah, 14Bh
Address: 14Ch 14Dh
Address: 14Eh 14Fh
PLS 0/PWM 0
frequency setting
PLS 1/PWM 1
frequency setting
PLS 2/PWM 2
frequency setting
PLS 3/PWM 3
frequency setting
K0 to K100
K0 to K100
K0 to K100
K0 to K100
Address: 158h 159h
Address: 15Ah 15Bh
Address: 15Ch 15Dh
Address: 15Eh 15Fh
PWM 0 Duty setting
PWM1 Duty setting
PWM2 Duty setting
PWM3 Duty setting
• Make sure to access shared memory by 2 word unit.
• Do not set a value out of the permitted range. It may
cause errors.
• Error detection upper limit of the unit is 1048.575 kHz.
(1048.575 kHz = FFFFFh)
When setting exceeds the limit, the value based on the
lower 20-bit is applied.
ATTENTION