3 – OPERATING MODE

 

 

Modes of operation are listed below and can be selected in the system menu “MODE” 

 
 

 
 

3.1

   

Weighing with totalization

  

 

( Rif. MODE : STD ) 

3.2

   

Weighing with partial zeroing

 

 

( Rif. MODE : AZZER ) 

3.3  

 

Animal weighing

 

   ( 

Rif. 

MODE 

PES-AN 

3.4

  

 Counting mode 

 

 

 

( Rif. MODE : COUNT ) 

3.5  

 

Unload weighing 

 

 

 

( Rif. MODE : SCAR) 

3.6

   

Checkweigher

     ( 

Rif. 

MODE 

TOLL 

3.7

   

Truck scales

    

 

 

 

( Rif. MODE : WBR ) 

3.8

   

Peak

 

 

    ( 

Rif. 

MODE 

PICCO 

3.9   Receipt batch  

   ( 

Rif. 

MODE 

RICETT 

3.10 

Simple 

batch 

 

    

( Rif. MODE : DOSAGG ) 

 

 

3.1 – Weighing with totalization 

In this operating mode, pressing the key 

 

it is possible to add the value of every single 

weight to the actual stored value. 
If a printer is connected to the indicator, a ticket will be printed according to the programmed 

parameters. 

 

3.1.1 - Reversal weighed  

Press keys  

    e 

 in sequence you can cancel a weighing operation performed 

incorrectly, if a sequence of weights is opened, namely: subtotal different from 0.  
The display shows "00000.0" and waits for the weight value to be reversed typed from the 
keyboard and confirmed with the button  

   ; the display shows "000000" and waits for the 

progressive of the receipt to reverse typed from the keyboard and confirmed with 

 

If there is a printer, a receipt is issued in accordance with the active mode with the given 
weight and number of pieces preceded by the sign "-". 

 

3.1.2 - Reprint receipt  

It is possible to reprint a receipt printed by pressing the key 

 

for 3 seconds . 

 

3.1.3 - Print Subtotal  

At the end of a sequence of weighings, the operator may ask to view and print the subtotal, ie 
the sum of the weighted up to that time.  
If you press and hold for 3 sec. button 

appears on the display for 3 seconds the value of 

the total in memory, and if a printer is connected, the subtotal printing operation is performed 
according to the programming mode active.  

After this  the subtotal is reset and its value is added to the total. 
 

3.1.4 - Print grand total  

The Grand Total is the sum of all SubTotal executed since the last reset of the same.  
If you press and hold for 3 sec. button 

 (with Subtotal = 0) the display will show for 3 

seconds the value of the Total General.  
If a printer is connected, a receipt is issued according to the programming mode activated.  

The operator also has the option to cancel the data displayed, or just to keep it in memory in 
which case the next Total Partial still be added to the current value.  
To proceed with the reset value of the press 

, while 

 

allows you to exit without 

resetting. 

 

3.1.5 - Print Total article  

Summary of Contents for SW22

Page 1: ...USER MANUAL WEIGHT INDICATOR MOD SW22 www odecasrl com...

Page 2: ...40 C READABILITY Max 60000 divisions LEGAL DIVISIONS Max 10000 or 2x6000 or 3x3000 DISPLAY Red LED 6 digit display h 20 mm LED 8 status LED KEYBOARD waterproof LOAD CELL POWER SUPPLY 5Vdc 5 120mA max...

Page 3: ...If led is off the weight is steady If led is on the SW21 is working with internal battery if led is blinking the battery is low and need to be recharged through the charger If led is on the weight on...

Page 4: ...ape Programming Menu Decimal Point Enter Tare 0 9 Numeric Tare Value Lock Unlock Tare n Tare n recall Multiple Tare 3 sec Clear Tare Sampling Tare Archive Creation PMU Setting Date Time setting Set po...

Page 5: ...SW22 4 User manual P1630830G Print total active code 3 Sec Print copy 3 sec Battery charge level Lock unlock keyboard Weighing delete Total by code Clear PMU...

Page 6: ...tares press keys in sequence and The display is ready for entering the identification code of the tare you want to enter or change 1 to 9 displaying T 1 the selection is made with the and and confirm...

Page 7: ...e button to return to the standard display mode 2 11 Display the battery charge level The level of charge of the internal battery of the instrument is divided on a scale from 1 to 10 Press the button...

Page 8: ...buzzer to sound a single beep 2 16 Keyboard Lock It is possible for security reasons to disable the operation of the keyboard Press and keys in sequence the display will show for 3 seconds the message...

Page 9: ...rom the keyboard and confirmed with If there is a printer a receipt is issued in accordance with the active mode with the given weight and number of pieces preceded by the sign 3 1 2 Reprint receipt I...

Page 10: ...f pieces weight average piece weight and net weight 3 4 1 Sampling The first step to be carried out in an operation of counting is sampling This can be done in two modes Sampling charge on the weighin...

Page 11: ...ight and number of pieces preceded by the sign 3 4 5 Display items PMU Net Weight Press keys and F2 in sequence switches the display mode of the number of pieces to that of the Average Piece Weight an...

Page 12: ...1 First weighing By pressing the weight on the scale is considered first weighing value associated with an identification number of memory which will allow the call at second weighing The maximum allo...

Page 13: ...W 22 provides the operator is that of Total for Item ie the sum of all items divided by code Press keys and in sequence and prints the total weight of all items with a value other than 0 in this case...

Page 14: ...o indicate the status of ongoing dosing and close the exits n 1 2 and 4 card optional I O When the net weight reaches the set threshold value the display shows u xx x indicating the end of the assay w...

Page 15: ...inal SW21 SW22 can be equipped optionally with an internal rechargeable battery at this stage it is possible to program the better off mode stand by in order to ensure the greatest possible independen...

Page 16: ...rd and then the new password The supervisor password 14556 allows the access in every condition 4 8 ST BAR Bar code printing It is possible to print an EAN 13 bar code on a single ticket ON Barcode pr...

Page 17: ...e used by SW22 to verify the correct reception this value is the operation XOR between characters ADDR and ETX EOT end transmission character EOT 04 Hex Weight request command Request ADDR CMD EOT 02...

Page 18: ...eration 7 chr TARE tare 7 chr AWS Single average weight unit g 7 chr PCS number of pieces 6 chr COD 1 numeric code n 1 6 chr COD 2 numeric code n 2 6 chr PROGR serial weight number preceded by P or F...

Page 19: ...ransmission character EOT 04 Hex 1 chr The fields MODE and ID are always in the form X IDYY where X represents the weight mode S I and U while YY represents the ID Code Single weight example STX M 1 1...

Page 20: ...rmed Storage weighing not performed ACK is chr 06 Hex NACK is chr 15 Hex Scale selection command Request ADDR CMD SCALE EOT 02 Hex or 80 Hex address SW BIL 1 o 2 04 Hex Positive answer from SW22 negat...

Page 21: ...Zero not performed ACK is chr 06 Hex NACK is chr 15 Hex Tare Command Request ADDR CMD PARAM ETX CHK EOT 02 Hex or 80 Hex address SW T Tare value 03 Hex checksum 04 Hex Where ADDR start transmission c...

Page 22: ...smission character EOT 04 Hex 1 chr The batch value or the formula number must be right justified and filled with space 20 HEX Positive answer from SW22 Negative answer from SW22 batch started batch n...

Page 23: ...CALW1 or CALW2 weight 03 Hex checksum 04 Hex Where ADDR start transmission character 1 chr CMD Command Code CALW scale number 1 or 2 5 chr PARAM calibration weight value 7 chr ETX end character ETX 03...

Page 24: ...he decimal separator is 2C Hex Transmission example STX N S 2 450 0 000 0 000 0 000001 000000 F000131 ETX 66 EOT The frequency of the transmission is depending from the Refresh weight Frequency throug...

Page 25: ...here ADDR start transmission character 1 chr CMD command code character M 1 chr SCALE scale number 1 or 2 1 chr NET net weight 7 chr TARE tare 7 chr GROSS gross weight or last weight 7 chr MODE weight...

Page 26: ...SW22 25 User manual P1630830G 6 CONNECTIONS...

Page 27: ...REFERENCE 13 REF REFERENCE 14 SIG SEGNALE ptf N 1 15 SIG SEGNALE ptf N 1 16 SIG SEGNALE ptf N 2 17 SIG SEGNALE PTF N 2 ALIMENTAZIONE ALIMENTAZIONE SEGNALE SEGNALE RIFERIMENTO RIFERIMENTO 6 2 Serial RS...

Page 28: ...al RS232 Connection for printer EPSON TMU295 and LX300 GND 7 3 TX Connettore COM 1 Connettore 25 Pin Maschio Strumento 7 9 STAMPANTE RX 6 5 Serial RS232 Connection for label printer Zebra GK420 and pr...

Page 29: ...8 57 9 58 59 60 61 62 63 64 65 A 66 B 67 C 68 D 69 E 70 F 71 G 72 H 73 I 74 J 75 K 76 L 77 M 78 N 79 O 80 P 81 Q 82 R 83 S 84 T 85 U 86 V 87 W 88 X 89 Y 90 Z 91 92 93 94 95 _ 96 97 a 98 b 99 c 100 d 1...

Page 30: ...me Europee EN 55011 EN 50082 1 89 336 EU EMC Directive adopted European Standard EN 55011 EN50082 1 Direttive CEE 73 23 e 93 68 sulla sicurezza elettrica in bassa tensione Norma Europea EN 61010 1 73...

Reviews: