![Odeca SW22 User Manual Download Page 20](http://html1.mh-extra.com/html/odeca/sw22/sw22_user-manual_3338129020.webp)
SW22
19
User
manual
P1630830G
02 Hex or (80 Hex + address SW)
P
I
04 Hex
Positive answer from SW22:
negative answer from SW22:
(Storage weighing performed)
(Storage
weighing
not
performed)
ID is the two characters ID weight Code
ACK is chr 06 Hex
NACK is chr 15 Hex
Second Weight operation command ( Only for weigh bridge )
Second weight request:
ADDR CMD
MODE
ID EOT
02 Hex or (80 Hex + address SW)
P
U
YY
04 Hex
ID is the two characters ID weight Code
Positive answer from SW22:
negative answer from SW22:
(Storage weighing performed)
(Storage
weighing
not
performed)
ACK is chr 06 Hex
NACK is chr 15 Hex
Scale selection command
Request :
ADDR CMD
SCALE
EOT
02 Hex or (80 Hex + address SW)
BIL
1 o 2
04 Hex
Positive answer from SW22:
negative answer from SW22:
(Scale selection performed)
(Scale selection not performed)
SCALE is the number of platform to be selected.
ACK is chr 06 Hex
NACK is chr 15 Hex
Fiscal memory weight value Command
Request :
ADDR CMD
MEM
EOT
02 Hex or (80 Hex + address SW)
F
XXXXXX
04 Hex
Positive answer from SW22:
negative answer from SW22:
(fiscal memory installed)
(fiscal memory not installed)
ADDR CMD MODE ID ACK EOT
ADDR
CMD NACK
EOT
ADDR CMD MODE ID ACK EOT
ADDR CMD MODE ID NACK EOT
ADDR CMD
SCALE ACK EOT
ADDR CMD
SCALE
NACK