3.6 – Checkweigher 

 

Selecting this option only works with Multi-field is not enabled, the 2 LEDs       :  are  used  to 

indicate if the weight scale is inside or outside (positive or negative) of a target range; if there 
is also the optional I / O outputs are also provided on the relay. 
In this mode, the sequence of commands 

 

and 

Set

 has a different meaning from the 

standard as it gives access to the procedure for selecting the mode of implementation of the 

audit tolerance. 

Menu items can be selected using the keys 

 and 

 are: 

1. Target 

2. Limit 
Selecting Target with the key 

 

you can enter a target value of weight and the amount of 

variation allowed in higher or lower. 
Selecting Limit (with the button

) the display will show the initials LL (lower limit) and after 

00000.0; type the desired value for the lower limit and confirm; the display shows the symbol 
UL (upper limit) and after 00000.0; Enter the desired value for the upper limit and confirm 
with

After the initial setup, any weight placed on the weighing pan is evaluated and the LED lights 

C1 indicates that the weight is less than the lower limit, the LED lights C2 indicates that the 
weight is greater than the upper limit while the ignition LEDs C1 and C2 indicates that the 

weight is within the two values. At the same time, if you have the optional relays, three relays 
are associated with the three LEDs provide similar outputs. 

 

3.7 – Truck scale  

 

3.7.1 – First weighing  

By pressing 

 

the weight on the scale is considered first weighing value associated with an 

identification number of memory which will allow the call at second weighing.  

The maximum allowed number of first open weighs (ie operations not closed by a second 
weighing) is 100.  

The print is made using the methods of programming active (type printer: TST1-DEVICE and 
card type: CARTEL). 
 

3.7.2 - Second weighing  

By pressing

 the weight on the scale is taken as the second weighing; Therefore, the 

operator will be asked to enter the ID code memory on the first weighing is carried out with 

respect to which the calculation of the net weight resulting from the difference between the 
two weighings.  

The calculated value is added to the total currently present in memory, and, if you have 
activated a commodity code, the same weight is added to the total also related to that product 

category.  
The print is made using the methods of programming active (type printer: TST1-DEVICE and 
card type: CARTEL). 

 

3.7.3 - Printing single weighing  

It is  also possible to make a single weighing operation which therefore will not be added to the 
queue of raw weighted assets.  

Pressing the keys and the weight on the scale is added to the total currently present in 
memory, and, if you have activated a commodity code, the same weight is added to the total 

also related to that product category.  
The print is made using the methods of programming active (type printer: TST1-DEVICE and 
card type: CARTEL). 

 

3.7.4 - Display queue first weighed  

By pressing the 

 and 

F1

 key, you can display the identification codes of the memory of the 

first weigh still open.  

Summary of Contents for SW22

Page 1: ...USER MANUAL WEIGHT INDICATOR MOD SW22 www odecasrl com...

Page 2: ...40 C READABILITY Max 60000 divisions LEGAL DIVISIONS Max 10000 or 2x6000 or 3x3000 DISPLAY Red LED 6 digit display h 20 mm LED 8 status LED KEYBOARD waterproof LOAD CELL POWER SUPPLY 5Vdc 5 120mA max...

Page 3: ...If led is off the weight is steady If led is on the SW21 is working with internal battery if led is blinking the battery is low and need to be recharged through the charger If led is on the weight on...

Page 4: ...ape Programming Menu Decimal Point Enter Tare 0 9 Numeric Tare Value Lock Unlock Tare n Tare n recall Multiple Tare 3 sec Clear Tare Sampling Tare Archive Creation PMU Setting Date Time setting Set po...

Page 5: ...SW22 4 User manual P1630830G Print total active code 3 Sec Print copy 3 sec Battery charge level Lock unlock keyboard Weighing delete Total by code Clear PMU...

Page 6: ...tares press keys in sequence and The display is ready for entering the identification code of the tare you want to enter or change 1 to 9 displaying T 1 the selection is made with the and and confirm...

Page 7: ...e button to return to the standard display mode 2 11 Display the battery charge level The level of charge of the internal battery of the instrument is divided on a scale from 1 to 10 Press the button...

Page 8: ...buzzer to sound a single beep 2 16 Keyboard Lock It is possible for security reasons to disable the operation of the keyboard Press and keys in sequence the display will show for 3 seconds the message...

Page 9: ...rom the keyboard and confirmed with If there is a printer a receipt is issued in accordance with the active mode with the given weight and number of pieces preceded by the sign 3 1 2 Reprint receipt I...

Page 10: ...f pieces weight average piece weight and net weight 3 4 1 Sampling The first step to be carried out in an operation of counting is sampling This can be done in two modes Sampling charge on the weighin...

Page 11: ...ight and number of pieces preceded by the sign 3 4 5 Display items PMU Net Weight Press keys and F2 in sequence switches the display mode of the number of pieces to that of the Average Piece Weight an...

Page 12: ...1 First weighing By pressing the weight on the scale is considered first weighing value associated with an identification number of memory which will allow the call at second weighing The maximum allo...

Page 13: ...W 22 provides the operator is that of Total for Item ie the sum of all items divided by code Press keys and in sequence and prints the total weight of all items with a value other than 0 in this case...

Page 14: ...o indicate the status of ongoing dosing and close the exits n 1 2 and 4 card optional I O When the net weight reaches the set threshold value the display shows u xx x indicating the end of the assay w...

Page 15: ...inal SW21 SW22 can be equipped optionally with an internal rechargeable battery at this stage it is possible to program the better off mode stand by in order to ensure the greatest possible independen...

Page 16: ...rd and then the new password The supervisor password 14556 allows the access in every condition 4 8 ST BAR Bar code printing It is possible to print an EAN 13 bar code on a single ticket ON Barcode pr...

Page 17: ...e used by SW22 to verify the correct reception this value is the operation XOR between characters ADDR and ETX EOT end transmission character EOT 04 Hex Weight request command Request ADDR CMD EOT 02...

Page 18: ...eration 7 chr TARE tare 7 chr AWS Single average weight unit g 7 chr PCS number of pieces 6 chr COD 1 numeric code n 1 6 chr COD 2 numeric code n 2 6 chr PROGR serial weight number preceded by P or F...

Page 19: ...ransmission character EOT 04 Hex 1 chr The fields MODE and ID are always in the form X IDYY where X represents the weight mode S I and U while YY represents the ID Code Single weight example STX M 1 1...

Page 20: ...rmed Storage weighing not performed ACK is chr 06 Hex NACK is chr 15 Hex Scale selection command Request ADDR CMD SCALE EOT 02 Hex or 80 Hex address SW BIL 1 o 2 04 Hex Positive answer from SW22 negat...

Page 21: ...Zero not performed ACK is chr 06 Hex NACK is chr 15 Hex Tare Command Request ADDR CMD PARAM ETX CHK EOT 02 Hex or 80 Hex address SW T Tare value 03 Hex checksum 04 Hex Where ADDR start transmission c...

Page 22: ...smission character EOT 04 Hex 1 chr The batch value or the formula number must be right justified and filled with space 20 HEX Positive answer from SW22 Negative answer from SW22 batch started batch n...

Page 23: ...CALW1 or CALW2 weight 03 Hex checksum 04 Hex Where ADDR start transmission character 1 chr CMD Command Code CALW scale number 1 or 2 5 chr PARAM calibration weight value 7 chr ETX end character ETX 03...

Page 24: ...he decimal separator is 2C Hex Transmission example STX N S 2 450 0 000 0 000 0 000001 000000 F000131 ETX 66 EOT The frequency of the transmission is depending from the Refresh weight Frequency throug...

Page 25: ...here ADDR start transmission character 1 chr CMD command code character M 1 chr SCALE scale number 1 or 2 1 chr NET net weight 7 chr TARE tare 7 chr GROSS gross weight or last weight 7 chr MODE weight...

Page 26: ...SW22 25 User manual P1630830G 6 CONNECTIONS...

Page 27: ...REFERENCE 13 REF REFERENCE 14 SIG SEGNALE ptf N 1 15 SIG SEGNALE ptf N 1 16 SIG SEGNALE ptf N 2 17 SIG SEGNALE PTF N 2 ALIMENTAZIONE ALIMENTAZIONE SEGNALE SEGNALE RIFERIMENTO RIFERIMENTO 6 2 Serial RS...

Page 28: ...al RS232 Connection for printer EPSON TMU295 and LX300 GND 7 3 TX Connettore COM 1 Connettore 25 Pin Maschio Strumento 7 9 STAMPANTE RX 6 5 Serial RS232 Connection for label printer Zebra GK420 and pr...

Page 29: ...8 57 9 58 59 60 61 62 63 64 65 A 66 B 67 C 68 D 69 E 70 F 71 G 72 H 73 I 74 J 75 K 76 L 77 M 78 N 79 O 80 P 81 Q 82 R 83 S 84 T 85 U 86 V 87 W 88 X 89 Y 90 Z 91 92 93 94 95 _ 96 97 a 98 b 99 c 100 d 1...

Page 30: ...me Europee EN 55011 EN 50082 1 89 336 EU EMC Directive adopted European Standard EN 55011 EN50082 1 Direttive CEE 73 23 e 93 68 sulla sicurezza elettrica in bassa tensione Norma Europea EN 61010 1 73...

Reviews: