Odeca SW22 User Manual Download Page 13

                                                                                                                                                   SW22 

 

12 

        User 

manual 

P1630830G 

To clear the queue of weighted press the button 

 

and confirm with 

 

Using the 

 button you can view the entire list. 

 

3.7.5 - Reprint Last ticket  

It is possible to reprint the last receipt accomplished by pressing the button 

for 3 sec. ; will 

be repeated printing of the last operation: first weighing, or weighing or weighing a single 
second. 

 

3.7.6 - Print Subtotal  

At the end of a sequence of weighings, the operator may ask to view and print the subtotal, ie 
the sum of the weighted up to that time.  
If you press and hold for 3 sec. button 

appears on the display for 3 seconds the value of 

the total in memory, and if a printer is connected, the subtotal printing operation is performed 
according to the programming mode active.  

After this  the subtotal is reset and its value is added to the total. 
 

3.7.7 - Print grand total  

The Grand Total is the sum of all SubTotal executed since the last reset of the same.  
If you press and hold for 3 sec. button 

 (with Subtotal = 0) the display will show for 3 

seconds the value of the Total General.  
If a printer is connected, a receipt is issued according to the programming mode activated.  

The operator also has the option to cancel the data displayed, or just to keep it in memory in 
which case the next Total Partial still be added to the current value.  
To proceed with the reset value of the press 

, while 

 

allows you to exit without 

resetting. 
 

3.7.8 - Print Total article  

The third operation of Total that the terminal SW-22 provides the operator, is that of Total for 

Item, ie the sum of all items divided by code.  
Press keys 

 and 

 

in sequence and prints the total weight of all items with a value other 

than 0; in this case, the reset request concerns the total of all codes (ENTER = YES; ESC = 

NO). 
 

3.8 - Peak Detection weight  

By selecting this mode, you can display the value of a weight (PEAK) detected during weighing.  
This feature is particularly useful to measure, for example, the breaking load of the materials.  
Pressing 

 and 

F1

 is enabled the peak display mode ; the display shows the message - 

PEAK every 5 seconds, alternating the maximum weight reached up to that point.  
Pressing 

 and 

F1

 again you return to the standard view of the weight on the balance. 

 

3.9 - Batch with recipes 

 

 Selecting the operating mode "Recipes" you can run an assay with a formula consisting of a 
maximum of two components. 

The maximum number of recipes can be stored is 50. 
Press keys 

 

and 

Set 

in sequence you enter the planning phase of the recipes. 

The display shows "r 00"; set the number of prescription to program and confirm with

; set 

the values in the sequence corresponding to the two components; if a component is not used, 
set the value to 0.0. 

After the inclusion of the second component, the display shows the number of recipe following 
the current one; press 

to confirm or 

to terminate. 

During the normal operating mode, to select the recipe number to be performed, dial the 

number from the keypad and confirm with 

COD

The cycle start command is given by pressing 

 

or closing the first of the two digital inputs of 

the I / O or serial port using the appropriate command. 
The batch can be performed either in LOAD or in DISCHARGE. 

Summary of Contents for SW22

Page 1: ...USER MANUAL WEIGHT INDICATOR MOD SW22 www odecasrl com...

Page 2: ...40 C READABILITY Max 60000 divisions LEGAL DIVISIONS Max 10000 or 2x6000 or 3x3000 DISPLAY Red LED 6 digit display h 20 mm LED 8 status LED KEYBOARD waterproof LOAD CELL POWER SUPPLY 5Vdc 5 120mA max...

Page 3: ...If led is off the weight is steady If led is on the SW21 is working with internal battery if led is blinking the battery is low and need to be recharged through the charger If led is on the weight on...

Page 4: ...ape Programming Menu Decimal Point Enter Tare 0 9 Numeric Tare Value Lock Unlock Tare n Tare n recall Multiple Tare 3 sec Clear Tare Sampling Tare Archive Creation PMU Setting Date Time setting Set po...

Page 5: ...SW22 4 User manual P1630830G Print total active code 3 Sec Print copy 3 sec Battery charge level Lock unlock keyboard Weighing delete Total by code Clear PMU...

Page 6: ...tares press keys in sequence and The display is ready for entering the identification code of the tare you want to enter or change 1 to 9 displaying T 1 the selection is made with the and and confirm...

Page 7: ...e button to return to the standard display mode 2 11 Display the battery charge level The level of charge of the internal battery of the instrument is divided on a scale from 1 to 10 Press the button...

Page 8: ...buzzer to sound a single beep 2 16 Keyboard Lock It is possible for security reasons to disable the operation of the keyboard Press and keys in sequence the display will show for 3 seconds the message...

Page 9: ...rom the keyboard and confirmed with If there is a printer a receipt is issued in accordance with the active mode with the given weight and number of pieces preceded by the sign 3 1 2 Reprint receipt I...

Page 10: ...f pieces weight average piece weight and net weight 3 4 1 Sampling The first step to be carried out in an operation of counting is sampling This can be done in two modes Sampling charge on the weighin...

Page 11: ...ight and number of pieces preceded by the sign 3 4 5 Display items PMU Net Weight Press keys and F2 in sequence switches the display mode of the number of pieces to that of the Average Piece Weight an...

Page 12: ...1 First weighing By pressing the weight on the scale is considered first weighing value associated with an identification number of memory which will allow the call at second weighing The maximum allo...

Page 13: ...W 22 provides the operator is that of Total for Item ie the sum of all items divided by code Press keys and in sequence and prints the total weight of all items with a value other than 0 in this case...

Page 14: ...o indicate the status of ongoing dosing and close the exits n 1 2 and 4 card optional I O When the net weight reaches the set threshold value the display shows u xx x indicating the end of the assay w...

Page 15: ...inal SW21 SW22 can be equipped optionally with an internal rechargeable battery at this stage it is possible to program the better off mode stand by in order to ensure the greatest possible independen...

Page 16: ...rd and then the new password The supervisor password 14556 allows the access in every condition 4 8 ST BAR Bar code printing It is possible to print an EAN 13 bar code on a single ticket ON Barcode pr...

Page 17: ...e used by SW22 to verify the correct reception this value is the operation XOR between characters ADDR and ETX EOT end transmission character EOT 04 Hex Weight request command Request ADDR CMD EOT 02...

Page 18: ...eration 7 chr TARE tare 7 chr AWS Single average weight unit g 7 chr PCS number of pieces 6 chr COD 1 numeric code n 1 6 chr COD 2 numeric code n 2 6 chr PROGR serial weight number preceded by P or F...

Page 19: ...ransmission character EOT 04 Hex 1 chr The fields MODE and ID are always in the form X IDYY where X represents the weight mode S I and U while YY represents the ID Code Single weight example STX M 1 1...

Page 20: ...rmed Storage weighing not performed ACK is chr 06 Hex NACK is chr 15 Hex Scale selection command Request ADDR CMD SCALE EOT 02 Hex or 80 Hex address SW BIL 1 o 2 04 Hex Positive answer from SW22 negat...

Page 21: ...Zero not performed ACK is chr 06 Hex NACK is chr 15 Hex Tare Command Request ADDR CMD PARAM ETX CHK EOT 02 Hex or 80 Hex address SW T Tare value 03 Hex checksum 04 Hex Where ADDR start transmission c...

Page 22: ...smission character EOT 04 Hex 1 chr The batch value or the formula number must be right justified and filled with space 20 HEX Positive answer from SW22 Negative answer from SW22 batch started batch n...

Page 23: ...CALW1 or CALW2 weight 03 Hex checksum 04 Hex Where ADDR start transmission character 1 chr CMD Command Code CALW scale number 1 or 2 5 chr PARAM calibration weight value 7 chr ETX end character ETX 03...

Page 24: ...he decimal separator is 2C Hex Transmission example STX N S 2 450 0 000 0 000 0 000001 000000 F000131 ETX 66 EOT The frequency of the transmission is depending from the Refresh weight Frequency throug...

Page 25: ...here ADDR start transmission character 1 chr CMD command code character M 1 chr SCALE scale number 1 or 2 1 chr NET net weight 7 chr TARE tare 7 chr GROSS gross weight or last weight 7 chr MODE weight...

Page 26: ...SW22 25 User manual P1630830G 6 CONNECTIONS...

Page 27: ...REFERENCE 13 REF REFERENCE 14 SIG SEGNALE ptf N 1 15 SIG SEGNALE ptf N 1 16 SIG SEGNALE ptf N 2 17 SIG SEGNALE PTF N 2 ALIMENTAZIONE ALIMENTAZIONE SEGNALE SEGNALE RIFERIMENTO RIFERIMENTO 6 2 Serial RS...

Page 28: ...al RS232 Connection for printer EPSON TMU295 and LX300 GND 7 3 TX Connettore COM 1 Connettore 25 Pin Maschio Strumento 7 9 STAMPANTE RX 6 5 Serial RS232 Connection for label printer Zebra GK420 and pr...

Page 29: ...8 57 9 58 59 60 61 62 63 64 65 A 66 B 67 C 68 D 69 E 70 F 71 G 72 H 73 I 74 J 75 K 76 L 77 M 78 N 79 O 80 P 81 Q 82 R 83 S 84 T 85 U 86 V 87 W 88 X 89 Y 90 Z 91 92 93 94 95 _ 96 97 a 98 b 99 c 100 d 1...

Page 30: ...me Europee EN 55011 EN 50082 1 89 336 EU EMC Directive adopted European Standard EN 55011 EN50082 1 Direttive CEE 73 23 e 93 68 sulla sicurezza elettrica in bassa tensione Norma Europea EN 61010 1 73...

Reviews: