ELECTRICAL CONFIGURATION
All PWC Series units are equipped with a standard 10-foot long service cord with
plug configurations and receptacle requirements as shown in this chart. PWC1211,
PWC1811, PWC2412 and PWC3612 units come with
LCDI
(Leakage Current Detection
& Interruption) devices that serve as a means of electrical protection.
CAUTION
DO NOT USE THE LCDI AS AN ON/OFF SWITCH FOR THE UNIT
All 3-phase models are equipped with locking plugs for added connection reliabil-
ity. Refer to the chart below for plug and receptacle details for all PWC models.
A DAMAGED POWER SUPPLY CORD MUST BE REPLACED WITH A
NEW POWER SUPPLY CORD OBTAINED FROM
OCEANAIRE, AND NOT REPAIRED
5
UNIT/MODEL
PLUG CONFIGURATION
RECEPTACLE
115 VOLT
PWC1211
PWC1811
NEMA 5-15R
208-230 VOLT SINGLE PHASE
PWC2412
PWC3612
NEMA 6-20R
208-230 VOLT SINGLE PHASE
PWC6012
NEMA 6-30R
208-230 VOLT 3-PHASE
PWC3632
NEMA L15-20R
208-230 VOLT 3-PHASE
PWC6032
NEMA L15-30R
460 VOLT 3-PHASE
PWC3634
PWC6034
NEMA L16-20R
15A-125 VOLT
NEMA 5-15P
20A-250 VOLT
NEMA 6-20P
30A-250 VOLT
NEMA 6-30P
20A-250 VOLT
NEMA L15-20P
30A-250 VOLT
NEMA L15-30P
20A-460 VOLT
NEMA L16-20P