- 15 -
=00, to turn off this function
=01, 30m
=02, 50m
=03, 100m
=04, 200m
=05, 300m
=06, 500m
=07, 1000m
=08, 2000m
Example
: W000000,006,06
When tracker moves out of this square scope, it will send out an SMS alarm.
12.2 Geo-fence Alarm
Command
: W******,017,X or W******,117,X
Description
: Turns on Geo-fencing alarm. When the tracker moves in/out the preset scope, it will send an
SMS alarm to the authorized phone number for SOS.
Note
:
1. 017 is for alarm when tracker moves out the preset scope;
2. 117 is for alarm when tracker moves in.
3. X is the coordinates which include: Lower-left X,Lower-left Y,Upper-right X,Upper-right Y
4. Lower-left X should be less than Upper-right X;
5. All longitudes and latitudes should be in ASCII format as follows:-
Longitude: DDDMM.MMMM,E/W. 4 places of decimal. ‘0’ is needed to be stuffed if no value available.
Latitude: DDMM.MMMM,N/S. 4 places of decimal. ‘0’ is needed to be stuffed if no value available;
6. Send W******,006,00 to turn off Geo-fence function.
Example
:
W000000,017,11404.0000,E,2232.0010,N,11505.1234,E,2333.5678,N
W000000,117,11404.0000,E,2232.0010,N,11505.1234,E,2333.5678,N
Remarks:
1. Only one alarm can be set in either In or Out;
2. Only one alarm can be set in either Movement Alarm or Geo-fence Alarm.
13. Output Control
13.1 Output Control (Immediate)
Command
: W******,020,P,F
Description
: Send this command to control the Output of OCB-VT-013
Note
:
P=1, Output1
P=2, Output2
P=3, Output3