Identifikationssystem OBID
®
Montageanleitung ID ZK.AB-A
FEIG ELECTRONIC GmbH
M00500.0de-ID-B.DOC
Seite 41 von 52
4.5 How to configurate the relay holding time
The holding time of the built-in relay may be adjusted by the user between 0,5 and 9 s. The
factory-alignment is 4 seconds.
Bring the
“Masterkarte“ into
the antenna field and
leave it there until the
desired relay holding
time appears.
H0 = 0,5 seconds
H1 = 1 second
H2 = 2 seconds
...
H9 = 9 seconds
0DV
WHUND
UWH
l
After the memory
address 190
(9.0)
l
an
“M“
1
appears on
the display
l
After that, relay
holding times are
counted from
“H0“
to
“H9“
2
Remove the
“Masterkarte“ from
the antenna field as
soon as the relay
holding time has been
reached
(example: H5)
0
DV
WH
UND
UWH
l
The display lights up
continuously for
approx. 3 s
l
After that, the
display flashes for
about 6s
Bring the
“Masterkarte“ into
the detec-tion area of
ID ZK.AB-A, as long
as the display is
flashing.
0DV
WHUND
UWH
l
When the relay
holding time (H5 = 5
seconds) is program-
med, the right deci-
mal point will light up
The “Masterkarte“
may now be removed.
Programming of the
relay holding time is
now completed.
0
DV
WH
UND
UWH
l
The
display
goes
out.
1
only if a factory “Masterkarte“ is used
2
the current relay holding time is indicated by the right decimal point