Identifikationssystem OBID
®
Montageanleitung ID ZK.AB-A
FEIG ELECTRONIC GmbH
M00500.0de-ID-B.DOC
Seite 31 von 52
RO GN GND IN1
+/
≈
-/
≈
NC COM NO ASW EA1 EA2
X1
X2
X3
3.3 Reader connection
Notice:
There is an option for connecting an external antenna (ID ZK.ANT-A) to ID ZK.AB-A.
Installation instructions are to be found in chapter 3.4, Connection of an external antenna.
The reader is connected by the connecting board (see also: illustration 4: connecting board), which
is locked into the lower part of the housing.
Illustration 4: connecting board of ID ZK.AB-A
Terminal
Function
Strip
Name
ID ZK.AB-A
X2
+ /
≈
Power supply (DC+,DC-,AC
≈
)
- /
≈
Power supply(DC+,DC-,AC
≈
)
NC
Relay – NC
COM
Relay – COM
NO
Relay – NO
ASW
-
EA1
Connection of external antenna
(ID ZK.ANT-A)
EA2
Connection of external antenna
(ID ZK.ANT-A)
X1
RO
Red LED
(ID ZK.ANT-A)
GN
Green LED
(ID ZK.ANT-A)
GND
Internal GND
(ID ZK.ANT-A)
IN1
-
Chart 1: terminal connection plan of connecting board (ID ZK.AB-A)