P1PVKY / P1PVCDKY
Installation & Service Instructions
030099-347
pg 13 of 14
© Copyright 2007 OASIS Corporation
Cleaning and Sanitising Instructions:
This procedure should be used for initial cleaning prior to commissioning and also for on-site
sanitization. The diagram below illustrates the water circuit used in all PV-DC model coolers:
No
Part No
Description
1
028913-002
JG FITTING, BULKHEAD CONNECTOR
2
029959-002
TUBING, 1/4"
3
029199-003
JG FITTING, TEE PIECE, 1/4"
4
034277-002
JG FITTING, 1/4" BSP
5
034613-001
SOLENOID VALVE 230V
6
030552-101
JG FITTING, 3/8" TO 1/4" REDUCER
7
028672-001
CARTRIDGE, HALF SET
8
035351-002
CHECK VALVE
9
034663-001
WATER OUTLET MOULDED
10
034625-001
SPOUT, WATER OUTLET
11
034506-001
COOLING TANK, HEAD
12
030858-407
O-RING
13
034507-002
COOLING TANK, BASE
14
035023-001
DRAIN TUBE, 3/8" ID
15
033970-003
DRAIN VALVE ASSY
Equipment:
•
Household bleach (5% sodium hypochlorite)
•
Mild soap solution
•
Plastic bucket
•
One 12” length of
¼
”OD plastic tubing
Preparation of Filter Cleaning Cartridge:
•
In order to get cleaning solution into contact with all of the water-contact surfaces it is
recommended that you prepare a filter cleaning cartridge. This should consist of an empty
filter housing and head assembly (i.e. does not contain a filter media). Proprietary systems are
available from the major reputable suppliers of fittings which have
¼
” push-fit inlet and outlet
suitable for use with the tubing contained in OASIS coolers.
•
To prepare the cleaning cartridge, place 1 ml (1/4 tsp) of the sodium hypochlorite solution into
the empty housing and then re-fit the head
Sanitisation Instructions:
•
Temporarily disconnect the water cooler from the mains water supply