background image

P1PVKY / P1PVCDKY 

Installation & Service Instructions 

 

 
 

 

 

030099-347 

pg 13 of 14  

         © Copyright 2007 OASIS Corporation 

Cleaning and Sanitising Instructions: 

 
This procedure should be used for initial cleaning prior to commissioning and also for on-site 
sanitization. The diagram below illustrates the water circuit used in all PV-DC model coolers: 
 

        

   

No

Part No

Description

1

028913-002

JG FITTING, BULKHEAD CONNECTOR

2

029959-002

TUBING, 1/4"

3

029199-003

JG FITTING, TEE PIECE, 1/4"

4

034277-002

JG FITTING, 1/4" BSP

5

034613-001

SOLENOID VALVE 230V

6

030552-101

JG FITTING, 3/8" TO 1/4" REDUCER

7

028672-001

CARTRIDGE, HALF SET

8

035351-002

CHECK VALVE

9

034663-001

WATER OUTLET MOULDED

10

034625-001

SPOUT, WATER OUTLET

11

034506-001

COOLING TANK, HEAD

12

030858-407

O-RING

13

034507-002

COOLING TANK, BASE

14

035023-001

DRAIN TUBE, 3/8" ID

15

033970-003

DRAIN VALVE ASSY

 
Equipment: 

 

Household bleach  (5% sodium hypochlorite) 

 

Mild soap solution 

 

Plastic bucket 

 

One 12” length of 

¼

”OD plastic tubing  

 

Preparation of Filter Cleaning Cartridge: 

 

In order to get cleaning solution into contact with all of the water-contact surfaces it is 
recommended that you prepare a filter cleaning cartridge. This should consist of an empty 
filter housing and head assembly (i.e. does not contain a filter media). Proprietary systems are 
available from the major reputable suppliers of fittings which have 

¼

” push-fit inlet and outlet 

suitable for use with the tubing contained in OASIS coolers. 

 

To prepare the cleaning cartridge, place 1 ml (1/4 tsp) of the sodium hypochlorite solution into 
the empty housing and then re-fit the head 

 

Sanitisation Instructions: 

 

Temporarily disconnect the water cooler from the mains water supply 

Summary of Contents for P1PVCDKY

Page 1: ...INSTALLATION SERVICE INSTRUCTIONS P1PVKY P1PVCDKY Contents...

Page 2: ...ion Cooler Installation General Troubleshooting Guidelines Cleaning and Sanitising Instructions Technical Specification Product Dimensions Height 1 110 mm Width 320 mm Depth 345 mm Net Weight 23 kg Fi...

Page 3: ...t Cold water temperatures may be adjusted via a slotted screw on the body of the control can be accessed through wires on the condenser Turning this screw in the clockwise direction will make the wate...

Page 4: ...g The entire internal water circuit and all the components which come in contact with water are food grade NSF WRAS approved Mounting Feet The unit is supplied with 4 mounting feet packed inside the f...

Page 5: ...n place e That the cooler is clean and dust free 5 Install your filtration system see relevant section in this manual 6 Flush out the water cooler a Connect the water supply to the bulkhead fitting at...

Page 6: ...g any shut off valve fitted to the installation or temporarily disconnecting the cooler from the mains Disconnect the cooler from the power supply Remove the top from the unit remove the two screws at...

Page 7: ...rward Remove the door from the cooler The inlet pipe is now visible on the left hand side of the filter compartment Installing the filter system It is recommended that you use a filter system with pus...

Page 8: ...e cooler in direct sunlight Do not locate the cooler next to a radiator Do not locate the cooler within or directly adjacent to toilet facilities Do not locate the cooler in constantly damp areas bene...

Page 9: ...l isolation valves Sanitisation EPDWA guidelines state All coolers must be sanitized before commissioning When a customer signs up to the sanitisation program the cooler should be sanitized every 6 mo...

Page 10: ...of installation g Level the machine using the adjustable feet 6 Connect the water cooler to a potable mains water supply OASIS recommend the use of an EPDA recognised installation kit that includes a...

Page 11: ...thermostat setting turn anti clockwise to increase the temperature setting of the cold water Disconnect the power from the unit and allow the the ice inside the cooler to melt Water dispensed from th...

Page 12: ...y Instructions Isolate the water cooler from the mains water supply this may be done by closing any shut off valve fitted to the installation or temporarily disconnecting the cooler from the mains Dis...

Page 13: ...0858 407 O RING 13 034507 002 COOLING TANK BASE 14 035023 001 DRAIN TUBE 3 8 ID 15 033970 003 DRAIN VALVE ASSY Equipment Household bleach 5 sodium hypochlorite Mild soap solution Plastic bucket One 12...

Page 14: ...ove the Filter Cleaning Cartridge Reconnect the blue tube to the tee piece or re install the filter system Reconnect the cooler to the mains water supply General Cabinetry Cleaning It is recommended t...

Reviews: