background image

P1PVKY / P1PVCDKY 

Installation & Service Instructions 

 

 
 

 

 

030099-347 

pg 3 of 14  

         © Copyright 2007 OASIS Corporation 

General Information: 

 

The P1PVKY & P1PVCDKY are cold and ambient water coolers designed for connection to a 
mains supply of potable water. The cooler should not be connected to water supplies of 
unknown bacterial quality or those that are not already fit for human consumption. The machine 
should only be connected to a potable drinking water supply 

 

This unit is suitable for indoor use in domestic, commercial & industrial locations. They should 
not be sited in locations where they may be subjected to rain or snow 

 
Cooling System: 

 

The P1PVKY & P1PVCDKY models use the OASIS Pressure Vessel Direct Chill (PVDC) 
cooling tank system. The cooling tank is manufactured from 304 Stainless Steel which is non-
corrosive and inert.  

 

The cold water temperature is preset at the factory at approximately 7°C – the water temperature 
is controlled by a thermostat that is located on the back of the unit. Cold water temperatures may 
be adjusted via a slotted screw on the body of the control (can be accessed through wires on the 
condenser). Turning this screw in the clockwise direction will make the water colder (and vice 
versa) 

 

The significant benefit of the OASIS PVDC system when compared to so-called “coil on Coil” 
Direct Chill systems is the increased quantities of cold water available on demand.  

 

Ambient Water Circuit: 

 

The water in the ambient water circuit is not cooled - the temperature of the water will be the 
same as the temperature of the water that comes out of the building water supply and the 
ambient room temperature. The ambient water should be flushed after long periods of non use 

 

Compressor: 

 

The compressor operates at 220-240V and at 50Hz. It uses the hydrofluorocarbon refrigerant 
R134a which is a non-Ozone depleting substance with a Global Warming Potential of 1,300. 
The compressor is controlled by an electromechanical thermostat that controls the temperature 
of the water in the direct chill unit 

 

Cup Dispenser: 

 

The P1PVCDKY contains an integrated cup dispenser built into the top of the cooler. This is the 
only difference between the P1PVKY and P1PVCDKY models 

 

 

Summary of Contents for P1PVCDKY

Page 1: ...INSTALLATION SERVICE INSTRUCTIONS P1PVKY P1PVCDKY Contents...

Page 2: ...ion Cooler Installation General Troubleshooting Guidelines Cleaning and Sanitising Instructions Technical Specification Product Dimensions Height 1 110 mm Width 320 mm Depth 345 mm Net Weight 23 kg Fi...

Page 3: ...t Cold water temperatures may be adjusted via a slotted screw on the body of the control can be accessed through wires on the condenser Turning this screw in the clockwise direction will make the wate...

Page 4: ...g The entire internal water circuit and all the components which come in contact with water are food grade NSF WRAS approved Mounting Feet The unit is supplied with 4 mounting feet packed inside the f...

Page 5: ...n place e That the cooler is clean and dust free 5 Install your filtration system see relevant section in this manual 6 Flush out the water cooler a Connect the water supply to the bulkhead fitting at...

Page 6: ...g any shut off valve fitted to the installation or temporarily disconnecting the cooler from the mains Disconnect the cooler from the power supply Remove the top from the unit remove the two screws at...

Page 7: ...rward Remove the door from the cooler The inlet pipe is now visible on the left hand side of the filter compartment Installing the filter system It is recommended that you use a filter system with pus...

Page 8: ...e cooler in direct sunlight Do not locate the cooler next to a radiator Do not locate the cooler within or directly adjacent to toilet facilities Do not locate the cooler in constantly damp areas bene...

Page 9: ...l isolation valves Sanitisation EPDWA guidelines state All coolers must be sanitized before commissioning When a customer signs up to the sanitisation program the cooler should be sanitized every 6 mo...

Page 10: ...of installation g Level the machine using the adjustable feet 6 Connect the water cooler to a potable mains water supply OASIS recommend the use of an EPDA recognised installation kit that includes a...

Page 11: ...thermostat setting turn anti clockwise to increase the temperature setting of the cold water Disconnect the power from the unit and allow the the ice inside the cooler to melt Water dispensed from th...

Page 12: ...y Instructions Isolate the water cooler from the mains water supply this may be done by closing any shut off valve fitted to the installation or temporarily disconnecting the cooler from the mains Dis...

Page 13: ...0858 407 O RING 13 034507 002 COOLING TANK BASE 14 035023 001 DRAIN TUBE 3 8 ID 15 033970 003 DRAIN VALVE ASSY Equipment Household bleach 5 sodium hypochlorite Mild soap solution Plastic bucket One 12...

Page 14: ...ove the Filter Cleaning Cartridge Reconnect the blue tube to the tee piece or re install the filter system Reconnect the cooler to the mains water supply General Cabinetry Cleaning It is recommended t...