background image

P1PVKY / P1PVCDKY 

Installation & Service Instructions 

 

 
 

 

 

030099-347 

pg 6 of 14  

         © Copyright 2007 OASIS Corporation 

8.

 

Replace the carton over the top of the cooler 

 
9.

 

The cooler is now ready for transportation to the customer’s premises 

 
 

NOTE: Whenever you transport the cooler to or from your premises, you should ensure that a 

shipping bag is placed over the cooler. This will prevent damage to the cabinet caused by coolers 

rubbing against one another in the back of the van or lorry 

 

 

Draining the Water Cooler: 

 

Isolate the water cooler from the mains water supply – this may be done by closing any shut-off 
valve fitted to the installation or temporarily disconnecting the cooler from the mains 

 

Disconnect the cooler from the power supply 

 

Remove the top from the unit – remove the two screws at the rear of the top, and lift off the lid 
assembly 

                       

                

 

 

Looking down on the unit, disconnect the cold water inlet as shown in the diagram below 

 

 

Open the drain valve at the rear of the unit 

 

Remove the screw holding the plug in position 

 

Rotate the plug anti-clockwise and pull from the drain body 

 

Allow water to drain from the valve 

 

The drain is located 280mm from the floor – ensure that you place a container under the valve 
prior to opening it. The container needs to have a minimum capacity of 2 litres 

 

Re-assemble the cooler by following the above instructions in the reverse order 

Summary of Contents for P1PVCDKY

Page 1: ...INSTALLATION SERVICE INSTRUCTIONS P1PVKY P1PVCDKY Contents...

Page 2: ...ion Cooler Installation General Troubleshooting Guidelines Cleaning and Sanitising Instructions Technical Specification Product Dimensions Height 1 110 mm Width 320 mm Depth 345 mm Net Weight 23 kg Fi...

Page 3: ...t Cold water temperatures may be adjusted via a slotted screw on the body of the control can be accessed through wires on the condenser Turning this screw in the clockwise direction will make the wate...

Page 4: ...g The entire internal water circuit and all the components which come in contact with water are food grade NSF WRAS approved Mounting Feet The unit is supplied with 4 mounting feet packed inside the f...

Page 5: ...n place e That the cooler is clean and dust free 5 Install your filtration system see relevant section in this manual 6 Flush out the water cooler a Connect the water supply to the bulkhead fitting at...

Page 6: ...g any shut off valve fitted to the installation or temporarily disconnecting the cooler from the mains Disconnect the cooler from the power supply Remove the top from the unit remove the two screws at...

Page 7: ...rward Remove the door from the cooler The inlet pipe is now visible on the left hand side of the filter compartment Installing the filter system It is recommended that you use a filter system with pus...

Page 8: ...e cooler in direct sunlight Do not locate the cooler next to a radiator Do not locate the cooler within or directly adjacent to toilet facilities Do not locate the cooler in constantly damp areas bene...

Page 9: ...l isolation valves Sanitisation EPDWA guidelines state All coolers must be sanitized before commissioning When a customer signs up to the sanitisation program the cooler should be sanitized every 6 mo...

Page 10: ...of installation g Level the machine using the adjustable feet 6 Connect the water cooler to a potable mains water supply OASIS recommend the use of an EPDA recognised installation kit that includes a...

Page 11: ...thermostat setting turn anti clockwise to increase the temperature setting of the cold water Disconnect the power from the unit and allow the the ice inside the cooler to melt Water dispensed from th...

Page 12: ...y Instructions Isolate the water cooler from the mains water supply this may be done by closing any shut off valve fitted to the installation or temporarily disconnecting the cooler from the mains Dis...

Page 13: ...0858 407 O RING 13 034507 002 COOLING TANK BASE 14 035023 001 DRAIN TUBE 3 8 ID 15 033970 003 DRAIN VALVE ASSY Equipment Household bleach 5 sodium hypochlorite Mild soap solution Plastic bucket One 12...

Page 14: ...ove the Filter Cleaning Cartridge Reconnect the blue tube to the tee piece or re install the filter system Reconnect the cooler to the mains water supply General Cabinetry Cleaning It is recommended t...