Hazards encountered by the combination of water and electricity
•
The combination of water and electricity can lead to death or severe injury from electrocution, if the unit is incorrectly
connected or misused.
•
Prior to reaching into the water, always switch off the mains voltage to all units used in the water.
Correct electrical installation
•
Electrical installations must meet the national regulations and may only be carried out by a qualified electrician.
•
A person is regarded as a qualified electrician if, due to his/her vocational education, knowledge and experience, he
or she is capable of and authorised to judge and carry out the work commissioned to him/her. This also includes the
recognition of possible hazards and the adherence to the pertinent regional and national standards, rules and regula-
tions.
•
The device may only be connected if the electrical data of the device and the power supply coincide. The device data
is to be found on the device type plate, on the packaging or in this manual.
•
For your own safety, please consult a qualified electrician.
•
Ensure that the unit is fused for a
rated fault current of max. 30
mA by means of a fault current protection device.
•
Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
•
Minimum safety distance between the unit and the water: 2 m.
•
Protect the plug connections from moisture.
•
Only plug the unit into a correctly fitted socket.
Safe operation
•
Never operate the unit if either the electrical cables or the housing are defective!
•
Do not carry or pull the unit by its electrical cable.
•
Route cables/hoses such that they are protected from damage and do not present a tripping hazard.
•
Only open the unit housing or its attendant components, when this is explicitly required in the operating instructions.
•
Only carry out work on the unit that is described in this manual. If problems cannot be overcome, please contact an
authorised customer service point or, when in doubt, the manufacturer.
•
Only use original spare parts and accessories for the unit.
•
Never carry out technical modifications to the unit.
•
Power connection cables cannot be replaced. If a cable is damaged, dispose of the respective unit or components.
•
Only operate the unit if no persons are in the water.
•
The unit, the connections and plugs are not water-proof and must not be routed or installed in water.
•
Keep the socket and power plug dry.
Installation
Use hoses that are suitable for a pressure of at least 1 bar.
How to proceed:
A
•
BioPress 6000/10000: Shorten stepped hose adapters such that the connection opening coincide with the hose di-
ameter. This helps to avoid pressure loss.
•
Push the union nuts over the stepped hose adapters, push or turn on the stepped hose adapter, and secure with the
hose clips.
•
Insert the flat sealing ring or the O ring into the union nut for the black hose adapter and screw onto the pressure filter
inlet.
•
Insert the flat sealing ring including the flow indicator flap for the transparent stepped hose adapter, then screw onto
the pressure filter outlet.
The cleaning effect of the pressure filter can be checked at the transparent stepped hose adapter with flow indicator
flap.
Summary of Contents for BioPress 10000
Page 1: ...14833 12 14 BioPress 4000 6000 10000 14833 GAW_BioPress_A5_end_ 11 12 14 15 42 Seite 2...
Page 2: ...2 A...
Page 3: ...3...
Page 4: ...4...
Page 5: ...5...
Page 114: ...BG 114 BG OASE Living Water BioPress 4000 6000 10000 BG A A BioPress 4000 6000 10000 UVC 8...
Page 115: ...BG 115 30 mA 2 1 bar A BioPress 6000 10000...
Page 116: ...BG 116 2 m max 40 C B 2 5 2 U 12 V AC U 30 V DC 0 2 C UVC 10 C...
Page 118: ...BG 118 UVC UVC UVC UVC UVC UVC UVC F UVC UVC UVC 1 2 3 4 UVC 8000 UVC UVC 6 7 8 9 UVC UVC...
Page 119: ...BG 119 8 C UVC 60 1 UVC UVC 8000 UVC UVC UVC UVC UVC UVC...
Page 120: ...UK 120 UK OASE Living Water BioPress 4000 6000 10000 UA A BioPress 4000 6000 10000 8...
Page 121: ...UK 121 30 2 1 A BioPress 6000 10000...
Page 122: ...UK 122 2 max 40 C B 2 5 2 U 12 U 30 0 2 C 10 C...
Page 124: ...UK 124 F 1 2 3 4 8000 6 7 8 9...
Page 125: ...UK 125 8 C UVC 60 1 8 000...
Page 126: ...RU 126 RU OASE Living Water BioPress 4000 6000 10000 RU BioPress 4000 6000 10000 8...
Page 127: ...RU 127 30 2 1 A BioPress 6000 10000...
Page 128: ...RU 128 2 Aquamax max 40 C B 2 5 2 U 12 U 30 0 2 C 10 C...
Page 130: ...RU 130 F 1 2 3 4 8000 6 7 8 9...
Page 131: ...RU 131 8 C 60 1 8000...
Page 132: ...CN 132 CN OASE Living Water BioPress 4000 6000 10000 D A A BioPress 4000 6000 10000 UVC 8...
Page 133: ...CN 133 30mA 2 m 1 A BioPress 6000 10000 O...
Page 134: ...CN 134 2 max 40 C B 2 5 cm 2 U 12 V U 30 V 0 2 bar C 10 C...
Page 136: ...CN 136 UVC UVC UVC UVC UVC UVC F O 1 2 3 O 4 O 8000 O 6 O 7 8 O 9 O O O...
Page 137: ...CN 137 8 C 1 m 60 cm 8000...
Page 141: ...141...
Page 142: ...142...
Page 143: ...14833 04 16...