Storage/Winterization

●   Put the unit out of operation at water temperatures below 46 °F (8 °C) or, at the latest, when freezing temperatures are 

to be expected.

●   Thoroughly clean the unit, check for damage.
●   Ensure that the storage place is inaccessible to children.

Wear parts

The impeller unit is a wear part and is excluded from the warranty.

Disposal

Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further 
information about the recycling of this product can be obtained from your local municipal authority.

Issue

Cause

Solution

The unit is not 

performing its 

suction function

Power supply not connected

Connect pump power supply, check the supply lines to make sure 

the voltage is correct

Impeller blocked, shaft broken

Remove the front cover, and impeller cover to expose the 

impeller. Turn the impeller to ensure that it is not broken or 

jammed by debris. Also check to make sure that the ceramic 

shaft or bearings are not broken.

Fountain or spitter clogged

Check for kinks or obstructions in tubing or spitter.

Pump is not completely submerged Completely submerge pump in the water

Insufficient flow

Flow control closed too far

Adjust flow control

Screen clogged

Clean

Tubing blocked

Clean or replace tubing

Tubing kinked

Eliminate kink, replace tubing if it is damaged

Excessive flow loss in the 

tubing due to friction

○ Reduce tubing length to reduce frictional loss
○ Select larger adapter and hose diameter.

Pump overload. The flow is 

automatically stopped to protect 

the pump.

○ Clean the pump housing and impeller assembly
○ Reduce the ambient temperature (e.g. ensure that the specified 

water temperature is adhered to, avoid direct sunlight)

Pump is not completely submerged Completely submerge pump in the water
Impeller worn

Replace impeller assembly

Unit switches 

off after a short 

running period

Excessive soiled water

Clean impeller housing, bearing and impeller assembly on pump 

and clean fountain water

Impeller blocked, shaft broken

Remove the front cover, and impeller cover to expose the 

impeller. Turn the impeller to ensure that it is not broken or 

jammed by debris. Also check to make sure that the ceramic 

shaft or bearings are not broken.

Water temperature too high

Maximum water temperature: +95°F (+35 °C)

Troubleshooting

Summary of Contents for 525

Page 1: ...Fountain Pump 525 Operating instructions Notice d emploi Instrucciones de uso...

Page 2: ...of this product Fountain Pump 525 Prior to operating the unit please read the instructions of use carefully and fully familiarize yourself with the unit Ensure that all work on and with this unit is...

Page 3: ...in Pump 525 referred to in the following as unit may only be used as specified in the following For pumping clean water in indoor and outdoor fountains table fountains and statues Operation under obse...

Page 4: ...he water level at regular intervals Always place the unit below water level Attention The installed temperature sensor automatically turns the pump off if it is overloaded The pump automatically switc...

Page 5: ...o potentially cause injury to fingers and in rare cases damaging the ceramic shaft or rear bearing Use thick gloves when replacing the impeller assembly Cleaning the unit Regular cleaning of the pump...

Page 6: ...tions in tubing or spitter Pump is not completely submerged Completely submerge pump in the water Insufficient flow Flow control closed too far Adjust flow control Screen clogged Clean Tubing blocked...

Page 7: ...ated voltage Power consumption Max flow rate Max head height cord length connection for hoses Dimensions 525 45416 120V 60 Hz 0 6 A 42 W 525 GPH 7 9 ft 16 ft 1 2 5 8 3 4 4 38 x 2 36 x 3 35 in Fountain...

Page 8: ...525 constitue un excellent choix Avant d utiliser la pompe lisez les instructions attentivement et familiarisez vous parfaitement avec l appareil Assurez vous que tout travail effectu sur cet apparei...

Page 9: ...tien inspectez le cordon d alimentation pour vous assurer qu il n est pas endommag Ne pas retirer la broche de terre de la fiche du cordon d alimentation Avertissement Pour r duire le risque de choc l...

Page 10: ...liez l autre extr mit du tuyau l l ment de fontaine d sir Important L appareil se met en marche automatiquement lorsque la connexion lectrique est tablie 1 Mise en marche branchez la fiche dans la pri...

Page 11: ...ez les appareils et quipements lectriques mettez hors circuit et retirez la fiche de la prise lectrique avant de p n trer dans l eau Isolez l appareil avant d y effectuer tout travail S curisez l appa...

Page 12: ...ds dans la tubulure ou spitter La pompe n est pas compl tement immerg e Immergez compl tement la pompe dans l eau D bit insuffisant Contr le de d bit trop ferm Ajustez le contr le du d bit Filtre bouc...

Page 13: ...ominale Consommation lectrique Capacit de d bit Hauteur maximale de la t te Longueur du cordon Branchement pour flexibles Dimension 525 45416 120V 60 Hz 0 6 A 42 W 1987 LPH 2 4 m 5m 13 16 19 mm 111 x...

Page 14: ...ar este producto de Bomba para Fuentes 525 Antes de poner la unidad en operaci n por favor lea las instrucciones de uso cuidadosamente y completamente para conocer la unidad Aseg rese que cualquier tr...

Page 15: ...er la clavija de puesta a tierra del enchufe del cable el ctrico ADVERTENCIA Para reducir el riesgo de un choque el ctrico utilice nicamente en port til autocontenido fuentes no mayores de 1 5 metros...

Page 16: ...posicionamiento estable No alce la bomba con el cable el ctrico Tuber a Adaptador Bomba Inicio Atenci n La bomba nunca debe operar en seco Posibles consecuencias La bomba ser destruida Medidas de pro...

Page 17: ...tica fuerte que estar jalando el montaje hacia dentro de la bomba Esto podr a causar heridas a los dedos y en casos aislados podr a da ar la varilla cer mica o el soporte trasero Utilice guantes grue...

Page 18: ...mente sumergida Sumerge la bomba completamente en el agua Flujo insuficiente Control de flujo demasiado cerrado Ajuste el control de flujo La pantalla est obstruida Limpie Las tuber as est n bloqueada...

Page 19: ...ensi n nominal Consumo el ctrico Tasa de flujo m xima Columna de agua Longitud de cable Conexiones para tuber a Dimensiones 525 45416 120V 60 Hz 0 6 A 42 W 1987 LPH 2 4 m 5 m 13 16 19 mm 111 x 60 x 85...

Reviews: