background image

-  English  -

5

4

Questions, problems, missing parts? 

Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email 

us at [email protected].  Or visit our website at www.oase-livingwater.com

1.

Maintenance and cleaning

Attention! Dangerous electrical voltage

.

Possible consequences: 

Death or serious injuries.

Protective measures:

•  Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the 

units and installations (switch off and disconnect from the power supply) before reaching into the water.

•  Isolate the unit before starting any work.

•  Secure the unit to prevent unintentional switching on.

WARNING 

This pump uses a very strong magnet to achieve superior performance. When removing the impeller assembly there 

will be considerable magnetic force resisting the extraction of the impeller assembly. This is normal. Likewise when 

replacing the impeller assembly there will be a strong magnetic force pulling the assembly into the pump to potentially 

cause injury to fingers and in rare cases damaging the ceramic shaft or rear bearing. Use thick gloves when replacing 

the impeller assembly.  

Cleaning the unit

    

Regular cleaning of the pump may be necessary depending 

upon the environment in which it is operated. Clean the pump 

when it is visibly soiled or when a drop in performance is 

detected

Clean the unit with warm water using a soft brush.

    

Never use aggressive cleaning agents or chemical solutions. 

These could attack the housing surface or impair the function.

    

In the event of stubborn furring (calcium deposits), a common 

household cleaner free from vinegar and chlorine can be used. 

Subsequently, clean the pump thoroughly using warm water.

Cleaning the pump

1.

   

Disconnect the pump from the power source.

○ Disconnect the tubing.

2.

   

Remove the front cover and disassemble the impeller 

cover to expose the impeller assembly.  

3.

   

Remove the impeller assembly by gently pulling on 

the impeller blades.

4. 

  Use a soft cloth or brush to clean the impeller assembly 

and the inside of the impeller housing.

    

Check parts for damages such as cracked rotor, shaft 

or bearing, cracks in the magnet, and broken plastics. 

Replace parts if necessary.

5.

   Reassemble in the reverse order.

2.

3.

4.

!

Summary of Contents for 525

Page 1: ...Fountain Pump 525 Operating instructions Notice d emploi Instrucciones de uso...

Page 2: ...of this product Fountain Pump 525 Prior to operating the unit please read the instructions of use carefully and fully familiarize yourself with the unit Ensure that all work on and with this unit is...

Page 3: ...in Pump 525 referred to in the following as unit may only be used as specified in the following For pumping clean water in indoor and outdoor fountains table fountains and statues Operation under obse...

Page 4: ...he water level at regular intervals Always place the unit below water level Attention The installed temperature sensor automatically turns the pump off if it is overloaded The pump automatically switc...

Page 5: ...o potentially cause injury to fingers and in rare cases damaging the ceramic shaft or rear bearing Use thick gloves when replacing the impeller assembly Cleaning the unit Regular cleaning of the pump...

Page 6: ...tions in tubing or spitter Pump is not completely submerged Completely submerge pump in the water Insufficient flow Flow control closed too far Adjust flow control Screen clogged Clean Tubing blocked...

Page 7: ...ated voltage Power consumption Max flow rate Max head height cord length connection for hoses Dimensions 525 45416 120V 60 Hz 0 6 A 42 W 525 GPH 7 9 ft 16 ft 1 2 5 8 3 4 4 38 x 2 36 x 3 35 in Fountain...

Page 8: ...525 constitue un excellent choix Avant d utiliser la pompe lisez les instructions attentivement et familiarisez vous parfaitement avec l appareil Assurez vous que tout travail effectu sur cet apparei...

Page 9: ...tien inspectez le cordon d alimentation pour vous assurer qu il n est pas endommag Ne pas retirer la broche de terre de la fiche du cordon d alimentation Avertissement Pour r duire le risque de choc l...

Page 10: ...liez l autre extr mit du tuyau l l ment de fontaine d sir Important L appareil se met en marche automatiquement lorsque la connexion lectrique est tablie 1 Mise en marche branchez la fiche dans la pri...

Page 11: ...ez les appareils et quipements lectriques mettez hors circuit et retirez la fiche de la prise lectrique avant de p n trer dans l eau Isolez l appareil avant d y effectuer tout travail S curisez l appa...

Page 12: ...ds dans la tubulure ou spitter La pompe n est pas compl tement immerg e Immergez compl tement la pompe dans l eau D bit insuffisant Contr le de d bit trop ferm Ajustez le contr le du d bit Filtre bouc...

Page 13: ...ominale Consommation lectrique Capacit de d bit Hauteur maximale de la t te Longueur du cordon Branchement pour flexibles Dimension 525 45416 120V 60 Hz 0 6 A 42 W 1987 LPH 2 4 m 5m 13 16 19 mm 111 x...

Page 14: ...ar este producto de Bomba para Fuentes 525 Antes de poner la unidad en operaci n por favor lea las instrucciones de uso cuidadosamente y completamente para conocer la unidad Aseg rese que cualquier tr...

Page 15: ...er la clavija de puesta a tierra del enchufe del cable el ctrico ADVERTENCIA Para reducir el riesgo de un choque el ctrico utilice nicamente en port til autocontenido fuentes no mayores de 1 5 metros...

Page 16: ...posicionamiento estable No alce la bomba con el cable el ctrico Tuber a Adaptador Bomba Inicio Atenci n La bomba nunca debe operar en seco Posibles consecuencias La bomba ser destruida Medidas de pro...

Page 17: ...tica fuerte que estar jalando el montaje hacia dentro de la bomba Esto podr a causar heridas a los dedos y en casos aislados podr a da ar la varilla cer mica o el soporte trasero Utilice guantes grue...

Page 18: ...mente sumergida Sumerge la bomba completamente en el agua Flujo insuficiente Control de flujo demasiado cerrado Ajuste el control de flujo La pantalla est obstruida Limpie Las tuber as est n bloqueada...

Page 19: ...ensi n nominal Consumo el ctrico Tasa de flujo m xima Columna de agua Longitud de cable Conexiones para tuber a Dimensiones 525 45416 120V 60 Hz 0 6 A 42 W 1987 LPH 2 4 m 5 m 13 16 19 mm 111 x 60 x 85...

Reviews: