background image

-  English  -

3

2

Questions, problems, missing parts? 

Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email 

us at [email protected].  Or visit our website at www.oase-livingwater.com

      WARNINGS AND CAUTIONS SYMBOLS

Symbols used in these instructions

The symbols used in this operating manual have the following meanings:
          Risk of injury to persons due to dangerous electrical voltage.

This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are 

not taken.

          Risk of personal injury caused by a general source of danger.

This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are 

not taken.

Important! The unit is equipped with a permanent magnet. The magnetic field may affect the function of pacemakers.

          Important information for trouble-free operation.

!

Intended use

Fountain Pump 525, referred to in the following as “unit”, may only be used as specified in the following:
•  For 

pumping

 clean water in indoor and outdoor fountains, table fountains, and statues.

•  Operation under observance of the technical data. 
The following restrictions apply to the unit:

•  Do not use in swimming pools.

•  CAUTION - this pump has been evaluated for use with water only. 

•  Never run the unit without water.

•  Do not use for commercial or industrial purposes.

•  Do not use in conjunction with chemicals, food products, easily flammable or explosive substances.

•  Do not connect to the domestic water supply.

•  Do not exceed the voltage shown on the pump.

•  Do not remove the grounding pin from the power cord plug.

•  Inspect the power cord for damage before installation and maintenance.

•  WARNING - To reduce the risk of an electric shock, use only on portable self-contained fountains no larger than 5 feet in 

any direction.

Use other than that intended

This unit can be dangerous and cause harm if not used in accordance with these instructions. Any use not in accordance 

with these instructions or modification(s) to the unit will void the limited warranty.

!

Summary of Contents for 525

Page 1: ...Fountain Pump 525 Operating instructions Notice d emploi Instrucciones de uso...

Page 2: ...of this product Fountain Pump 525 Prior to operating the unit please read the instructions of use carefully and fully familiarize yourself with the unit Ensure that all work on and with this unit is...

Page 3: ...in Pump 525 referred to in the following as unit may only be used as specified in the following For pumping clean water in indoor and outdoor fountains table fountains and statues Operation under obse...

Page 4: ...he water level at regular intervals Always place the unit below water level Attention The installed temperature sensor automatically turns the pump off if it is overloaded The pump automatically switc...

Page 5: ...o potentially cause injury to fingers and in rare cases damaging the ceramic shaft or rear bearing Use thick gloves when replacing the impeller assembly Cleaning the unit Regular cleaning of the pump...

Page 6: ...tions in tubing or spitter Pump is not completely submerged Completely submerge pump in the water Insufficient flow Flow control closed too far Adjust flow control Screen clogged Clean Tubing blocked...

Page 7: ...ated voltage Power consumption Max flow rate Max head height cord length connection for hoses Dimensions 525 45416 120V 60 Hz 0 6 A 42 W 525 GPH 7 9 ft 16 ft 1 2 5 8 3 4 4 38 x 2 36 x 3 35 in Fountain...

Page 8: ...525 constitue un excellent choix Avant d utiliser la pompe lisez les instructions attentivement et familiarisez vous parfaitement avec l appareil Assurez vous que tout travail effectu sur cet apparei...

Page 9: ...tien inspectez le cordon d alimentation pour vous assurer qu il n est pas endommag Ne pas retirer la broche de terre de la fiche du cordon d alimentation Avertissement Pour r duire le risque de choc l...

Page 10: ...liez l autre extr mit du tuyau l l ment de fontaine d sir Important L appareil se met en marche automatiquement lorsque la connexion lectrique est tablie 1 Mise en marche branchez la fiche dans la pri...

Page 11: ...ez les appareils et quipements lectriques mettez hors circuit et retirez la fiche de la prise lectrique avant de p n trer dans l eau Isolez l appareil avant d y effectuer tout travail S curisez l appa...

Page 12: ...ds dans la tubulure ou spitter La pompe n est pas compl tement immerg e Immergez compl tement la pompe dans l eau D bit insuffisant Contr le de d bit trop ferm Ajustez le contr le du d bit Filtre bouc...

Page 13: ...ominale Consommation lectrique Capacit de d bit Hauteur maximale de la t te Longueur du cordon Branchement pour flexibles Dimension 525 45416 120V 60 Hz 0 6 A 42 W 1987 LPH 2 4 m 5m 13 16 19 mm 111 x...

Page 14: ...ar este producto de Bomba para Fuentes 525 Antes de poner la unidad en operaci n por favor lea las instrucciones de uso cuidadosamente y completamente para conocer la unidad Aseg rese que cualquier tr...

Page 15: ...er la clavija de puesta a tierra del enchufe del cable el ctrico ADVERTENCIA Para reducir el riesgo de un choque el ctrico utilice nicamente en port til autocontenido fuentes no mayores de 1 5 metros...

Page 16: ...posicionamiento estable No alce la bomba con el cable el ctrico Tuber a Adaptador Bomba Inicio Atenci n La bomba nunca debe operar en seco Posibles consecuencias La bomba ser destruida Medidas de pro...

Page 17: ...tica fuerte que estar jalando el montaje hacia dentro de la bomba Esto podr a causar heridas a los dedos y en casos aislados podr a da ar la varilla cer mica o el soporte trasero Utilice guantes grue...

Page 18: ...mente sumergida Sumerge la bomba completamente en el agua Flujo insuficiente Control de flujo demasiado cerrado Ajuste el control de flujo La pantalla est obstruida Limpie Las tuber as est n bloqueada...

Page 19: ...ensi n nominal Consumo el ctrico Tasa de flujo m xima Columna de agua Longitud de cable Conexiones para tuber a Dimensiones 525 45416 120V 60 Hz 0 6 A 42 W 1987 LPH 2 4 m 5 m 13 16 19 mm 111 x 60 x 85...

Reviews: