UM10413
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2011. All rights reserved.
User manual
Rev. 1 — 16 December 2011
138 of 268
NXP Semiconductors
UM10413
MPT612 User manual
0x98
previously addressed
with general call; data
byte received; NOT
ACK returned
read data byte or
0
0
0
0
switched to not-addressed SLV mode; no
recognition of own SLA or general call
address
read data byte or
0
0
0
1
switched to not-addressed SLV mode;
own SLA recognized; general call
address recognized if I2ADR[0] = logic 1
read data byte or
1
0
0
0
switched to not-addressed SLV mode; no
recognition of own SLA or general call
address. A start condition is transmitted
when the bus is free.
read data byte
1
0
0
1
switched to not-addressed SLV mode;
own SLA recognized; general call
address recognized if I2ADR[0] = logic 1.
A start condition is transmitted when the
bus is free.
0xA0
a stop condition or
repeated start
condition received
while still addressed
as SLV/REC or
SLV/TRX
no STDAT action
or
0
0
0
0
switched to not-addressed SLV mode; no
recognition of own SLA or general call
address
no STDAT action
or
0
0
0
1
switched to not-addressed SLV mode;
own SLA recognized; general call
address recognized if I2ADR[0] = logic 1
no STDAT action
or
1
0
0
0
switched to not-addressed SLV mode; no
recognition of own SLA or general call
address. A start condition is transmitted
when the bus is free.
no STDAT action
1
0
0
1
switched to not-addressed SLV mode;
own SLA recognized; general call
address recognized if I2ADR[0] = logic 1.
A start condition is transmitted when the
bus is free.
Table 136. Slave receiver mode
…continued
Status
code
(I2CSTAT)
Status of I
2
C-bus
and hardware
Application software response
Next action taken by I
2
C hardware
To/from I2DAT
To I2CON
STA STO SI
AA