background image

©2018 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners.

 

nVent reserves the right to change specifications without notice.

Raychem-IM-H55388-RayClicConnectionKits-EN-1805 

PN 473303-000

nVent.com

North America 

Tel +1.800.545.6258

Fax +1.800.527.5703

[email protected]

Europe, Middle East, Africa

Tel +32.16.213.511

Fax +32.16.213.604

[email protected]

Asia Pacific

Tel +86.21.2412.1688

Fax +86.21.5426.3167

[email protected]

Latin America

Tel +1.713.868.4800

Fax +1.713.868.2333

[email protected]

Summary of Contents for Raychem RayClic Series

Page 1: ...instructions To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed and to comply with the requirements of nVent agency certifications...

Page 2: ...1 splice 2 warning E 1 Cable lubricant RAYCLIC T TEE KIT Item Qty Description A 1 Tee B 2 Plastic cable ties C 3 Clips D 1 End seal E 3 Labels 1 splice 2 warning F 1 Cable lubricant RAYCLIC X CROSS K...

Page 3: ...pipe and attach with plastic cable ties Score around and down the outer jacket of the heating cable 3 1 8 inches from the end Allow enough extra heating cable to make service loops as required Make su...

Page 4: ...cut away 1 inch of the braid Pull exposed braid back over metal clip Using wire cutters cut away aluminum wrap Pull exposed braid back over metal clip IceStop and XL Trace Only HWAT Only nVent RAYCHEM...

Page 5: ...e compressed Repeat steps 2 through 7 for all remaining heating cable entries Using glass cloth tape attach heating cable to pipe Apply insulation cladding warning labels and yellow splice identificat...

Page 6: ...steps 2 through 9 pages 3 5 Attach connector to mounting bracket by pressing until it snaps into place Complete heating cable installation and install drip loops as shown Protect heating cable from sh...

Page 7: ...Remove the outer jacket Do not cut or damage inner jacket Using wire cutters cut away aluminum wrap close to braid and outer jacket Remove exposed braid Push end seal completely onto heating cable No...

Page 8: ...ating cable does not have aluminum wrap Only HWAT heating cables have the aluminum wrap under the braid Skip the aluminum wrap removal step for XL Trace and IceStop heating cables Heating cable cannot...

Page 9: ...detail heating cable operation refer to the appropriate installation and operating manual Instructions 1 Open the RayClic Cover 2 Set multimeter to AC voltage function 3 Insert multimeter test probes...

Page 10: ...cations without notice Raychem IM H55388 RayClicConnectionKits EN 1805 PN 473303 000 nVent com North America Tel 1 800 545 6258 Fax 1 800 527 5703 thermal info nvent com Europe Middle East Africa Tel...

Reviews: