ASSEMBLY INSTRUCTIONS
TT
TT
STEP 7
STEP 8
STEP 9
STEP 7
WARNING:Remove protective cover before assembling.
Note: If necessary for proper alignment of reflector sections,
loosen each bolt prior to further assembly and retighten after
sections are aligned.
STEP 8
Slide two reflector panels together.
threaded end of screw M6 X 10 and screw on cap nut loosely.
STEP 9
Slide reflector plate onto reflector panels.
end of screw M6 X 10 and screw on cap nut loosely. Repeat
procedure to complete the assembly of all four sections. Fully tighten
all of the screws in the rolled edge.
ASSEMBLY INSTRUCTIONS
Hardware Used
GG
HH
11. Screw gas hose (C) and regulator (E) onto propane
8
cylinder (not included). Do not cross-thread.
Every part of the heater shall be secure against displacement
and shall be constructed to maintain a fixed relationship between
essential parts under normal and reasonable conditions of
handling and usage. Parts not permanently secured shall be
designed so they cannot be incorrectly assembled and cannot be
improperly located or misaligned in removing or replacing during
cleaning or other servicing.
10. Slide 8 washers (GG) over the threaded ends of
reflectors spacers(FF). Attach reflector assembly to
head assembly (B). Place 8 washers (GG) over threaded
ends of reflector spacers(FF) sticking out through reflector
assembly and secure with wing nuts (HH).
Note: Do not overtighten.
x 6
x 3
C
JE
10
11
HH
Use a standard 20 lb. propane cylinder only.
(approximately 12.2 in. / 31cm. in diameter and 17.9 in.
/ 45.5cm high).
Use this heater only with a propane vapor
withdrawal supply system. See chapter 5 of the standard
for storage and handling of liquefied petroleum gas,
ANS/NFPA 58. Your local library or fire department
should have this book. Storage of an appliance indoors
is permissible only if the cylinder is disconnected and
removed from the appliance. A cylinder must be stored
outdoors in a well-ventilated area out of the reach of
children. A disconnected cylinder must have dust caps
tightly installed and must not be stored in a building,
garage or any other enclosed area. The maximum inlet
gas supply pressure: 250 psi /1750 kPa. The minimum
inlet gas supply pressure: 5 psi /35kPa. Manifold
pressure with regulator provided: 11 inch
C/ 2.74 kPa.
The pressure regulator and hose assembly supplied
with the appliance must be used. The installation must
conform with local codes, or in the absence of local
codes,with national fuel gas code, ANS Z223.1/NFPA54,
natural gas and propane Installation Code, CSA B149.1,
or propane storage and handling code, B149.2.
Wing nut
Regulator
Gas tank