Cassius Vertical Radiator Fixing Instructions

 

Please unpack your delivery carefully and inspect the radiator and contents 

 

any damages or shortages must be notified to your supplier within 3 days of 
delivery of your goods. 

SPECIFICATIONS FOR CASSIUS VERTICAL 

Materials 

Mild Steel 

Connections 

½ 

“Flow and

 Return 

Test Pressure 

8 Bar 

Testing Authority 

EN442 

Max operation pressure 

4 Bar 

Max working temperature  95c 

These can be cleaned using a soft damp cloth 
with a non-abrasive cleaning product. 

PLEASE  NOTE:  That  in  accordance  with  Part  L1  2006  of  the  Building  Regulations  and  BS7593:1992  code  of  practice  for  the 
treatment of hot water and central heating systems, we recommend flushing the heating system before installation of new 
radiators and then adding the correct quantity and type of inhibitor for use with the radiator and system to prevent corrosion. 
Damage caused to systems not protected by a suitable inhibitor will not be covered by the manufacturer warranty. It is the 
responsibility of the installer to ensure the correct use and suitability of the fixings provided. No liability for costs or damages 
arising from failure to do so can be accepted. 

Summary of Contents for Cassius

Page 1: ...aning product PLEASE NOTE That in accordance with Part L1 2006 of the Building Regulations and BS7593 1992 code of practice for the treatment of hot water and central heating systems we recommend flushing the heating system before installation of new radiators and then adding the correct quantity and type of inhibitor for use with the radiator and system to prevent corrosion Damage caused to syste...

Page 2: ......

Page 3: ... be very heavy products it is recommended you consult a qualified person if you are unsure about the suitability of the wall they are to be mounted on to take the weight It should only be filled with water and at a temperature below 100 C 212 F See table below for installation requirements If the temperature exceeds 48 C or 120 F please install a warning sign near the product to avoid burning and sc...

Page 4: ...n become a hazard for children as a This radiator is not designed to support unreasonable extra weight such as that of a child and b The radiator becomes hot during use Due to this we must stress that you should not allow children to climb grab play with the radiator or rails as this can cause accident or injury for the child from heat falling or the radiator being pulled off the wall CAUTION Plea...

Page 5: ...4 Position the towel rail in desired location check for level and mark four equal positions for the brackets 1 ...

Page 6: ...les in wall and insert wall plugs N B For false or studded walls different fixings can be purchased from your local DIY store Fix the wall brackets to the wall with screws provided and ensure a secure holding 2 3 ...

Page 7: ...g plug and bleeder valve and screw into top of radiator tighten with a spanner Apply PTFE tape to valves and screw into bottom of radiator tighten with a spanner 5 Rest radiator onto brackets and connect valves to household supply 4 ...

Page 8: ...7 INSTALLATION PROCEDURE ...

Page 9: ... to release air 2 Make sure the valve is fully open to allow water to run freely Some radiators may need diverter for water to flow properly around the unit Leak on the radiator Valve nut isloose Welding problem Tighten the valve nut Replace radiator Sound of whistling or water whooshing Radiator was not properly balanced when it was installed Re install Clanking sound The radiator was installed in...

Page 10: ... by you or where such goods have not been received back to us within 3 months of the replacement goods being received by yourselves A re stocking charge of 30 will be applied to all non faulty stock items that wish to be returned Special order and non stock products cannot be cancelled Where cancellation or alteration of orders is accepted by us you may be required to pay a restocking charge to co...