background image

15

Measures the individual power output (

Watts

) of the right leg and the left leg. Identifies 

their relative balance both in real-time and over the entire exercise session.
Once selected, the 

Balanced Power 

program continues to run in the background, 

collecting performance data, even while the user works out in other apps.
Performance data is displayed two ways, 

Standard

 and 

Enhanced.

 

Display Screens

Tap to switch between 

Standard

 and 

Enhanced.

Enhanced 

Also uses the bar graphs and line graph 

to display performance. 
Adds graphics to show the radial force 

generated by each leg. 
This identifies where force imbalance 

occurs during rotation.

Standard 

Bar graphs display the current (real time)

power generated by each leg and their 

relative symmetry. 

The line graph displays the percentage 

of balance between the left and right leg 

over the course of the session. 

In the screens at right, the upper screen 

shows that the power output between the 

right and left legs is balanced. 
The lower screen shows that the power 

output of the left leg is greater than the 

right leg and therefore imbalanced.

Balanced

Unbalanced

Balanced Power

To be balanced, the difference in power 

output between legs cannot be greater 

than 10%.

Summary of Contents for RB8

Page 1: ...NuStep RB8 Recumbent Bike user manual...

Page 2: ......

Page 3: ...10 11 Correct Riding Position 11 Display Screens 12 17 Pause Function 18 System Settings 19 21 User Settings 21 Exporting User Profile Data 22 Exporting Workout Summary 23 Preventive Maintenance 24 W...

Page 4: ...ike line which includes the RB8PRO and the RB8MAX continues NuStep s tradition of innovation and its mission to develop inclusive exercise equipment that can benefit users of virtually all fitness lev...

Page 5: ...not recommended by the manufacturer Never operate this equipment if it has a damaged cord or plug Keep cord away from heated surfaces Keep product away from heat sparks open flames and hot surfaces Ne...

Page 6: ...ans immediately Do not perform maintenance or repairs on this product while it is in use Maintenance activities shall performed by qualified service personnel Make sure the seat position and upper arm...

Page 7: ...RB8 place on a flat stable surface Adjust leveler feet as required The minimum amount of required free space around the RB8 unit is 24 inches 61 cm Additional free space is necessary to accommodate wh...

Page 8: ...tlet Route the AC adapter power cable in a way that prevents tripping hazards or damage to the adapter Avoid placing any pressure or strain on adapter cables jacks or plugs For adapter specifications...

Page 9: ...9 RB8 Feature Overview seat adjustment release lever swivel seat release lever leveler feet seat recline release lever dual touch screen display display console contact heart rate grip grab bar...

Page 10: ...il or floor 2 Lift the rear release lever to unlock seat 3 Swivel the seat in either direction seat swivels 360 and locks every 45 4 Release the lever to lock seat in position Lift rear lever to unloc...

Page 11: ...tments The exerciser s body position and the physical configuration of the machine varies depending on the exerciser s goals or needs Use the information here as a general guide or starting point for...

Page 12: ...ation The upper is the Home screen the lower is the Metric screen Metric Screen Displays information and settings icons as well as workout metrics including Time Level resistance Heart Rate Calories S...

Page 13: ...open the Performance Charts app Tap to open the Pace Partner app Displays performance metrics Pace RPM Watts Load METs or Balance tracked over the course of a workout To switch between performance ch...

Page 14: ...o complete Once the user begins cycling the screen displays their current pace and the target pace When on pace the user s cyclist is green and next to the target cyclist see above right When off pace...

Page 15: ...erformance Adds graphics to show the radial force generated by each leg This identifies where force imbalance occurs during rotation Standard Bar graphs display the current real time power generated b...

Page 16: ...ay video To return to the Trail Runner menu 1 Tap screen the title bar drops down 2 Tap on the back arrow in the title bar All video audio and other content included in Trail Runner and other NuStep a...

Page 17: ...e for their workout To open 1 Go to the NuStep Programs menu screen 2 Tap the Watts icon to open the settings screen 3 Tap Target edit icon to open set up screen a Use slider or tap to set Watts level...

Page 18: ...n also view a summary of their workout performance or end their workout session After reviewing the summary users can return to their workout end their workout or export their workout summary to a USB...

Page 19: ...htness change default settings view diagnostics change metric configuration view regulatory and software information To open go to the Metric screen tap the icon To adjust console volume or screen bri...

Page 20: ...pply changes The diagnostics screens display live and historical data for service technicians or those responsible for equipment maintenance The Historical Version screen requires a password to access...

Page 21: ...firm to apply change Users create and save a profile with their age weight sex To create go to the Metric screen 1 Tap the icon to open the User Settings screen 2 Tap into each field to enter age and...

Page 22: ...e into the USB port on the back of the display console 2 Tap the icon on the Metric screen to open the User Settings screen Skip this step if the profile screen launches automatically 3 Tap Export to...

Page 23: ...creen opens 1 Tap View Workout Summary to open summary screen Tap to view summary Tap to open summary Insert a USB drive into the USB port before working out to enable export Insert a USB drive into t...

Page 24: ...of usage that the product receives These are estimated intervals and you may need to increase or decrease the time period between preventive maintenance depending on your actual use I T E M T A S K F...

Page 25: ...he left side of the rear support cover A Manufacturer s name and address B Patent protection for the product C Model and serial number D Date of manufacture E Type B applied part for electrical safety...

Page 26: ...side of the rear support cover and a complete description of the problem so our product specialists can better assist you To reach a NuStep product specialist please contact Email support nustep com P...

Page 27: ...28A2025 0A0 to cable between 10 30 cm from the console connector The Laird ferrite may be substituted by other ferrites with equivalent technical specifications Standards UL 1647 CSA C22 2 68 Braking...

Page 28: ...particular installation If the equipment causes harmful interference to radio or television reception which can be determined by turning this equipment off and on the user is encouraged to try and cor...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...nuous improvement specifications and descriptions are subject to change without notice No part of this manual may be reproduced or transmitted in any form or by any means electronic or mechanical for...