Operating Instruction and Documentation
UNI-LIFT 5000 CLT / Plus
- 23 -
6.1 Driving on an obstacle
If the Safety-Star-System recognizes a difference of 40 mm between the platforms then it
switches off the lift.
6.1.1 Remove the object
Only trained and authorized staff is allowed to work with the DIP-switches! The
main-switch has to be switched off!
• Remove the cover of the operating unit and the control box.
• Press the button „Reset“ (1) and hold it. (see pic. 2, „Reset Achskontroller 1“)
pic. 2: circuit board in the control box
• Switch-off the main switch and wait 5 sec. Hold the reset button.
• Switch-on the main switch and wait 5 sec. Hold the reset button.
• Let go off the reset button.
• Move all the Dip-switch on position „off“.
• Move the Dip-switch 1 and 2 on position „on“.
•
Caution
: This procedure can only be done when the lift is
not
at the maximum
height.
• Carefully watch the car on the lift and its reaction.
• Press the „lifting“ button until the object can be removed.
• The side of the lift that is higher must be lowered with the help of the corresponding
Dip-switch. (see „Equalisation of the two lifting platforms“).
• After the equalizing of the runways, a reset has to be done.
• Move all the Dip-switches on position „off“.
Summary of Contents for UNI-LIFT 5000 CLT PLUS
Page 9: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 9 page for notice...
Page 12: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 12 3 3 Datasheet...
Page 13: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 13...
Page 14: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 14...
Page 15: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 15...
Page 16: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 16...
Page 17: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 17...
Page 18: ...Operating Instruction and Documentation UNI LIFT 5000 CLT Plus 18...