9.5 Changing the installation place
If the place of installation shall be changed, the new place has to be prepared in
according to the regulations of the first installation. The changing should be performed
in accordance with the following points:
• Raise the lift on approx. 1000 mm.
• Remove the cover of the hydraulic tubes.
• Loose the dowels.
• Lower the lift in the lowest position.
• Loose the plug of the power supply.
• If necessary loose the hydraulic hoses only on the operating unit.
• If necessary use blind plugs to close the hoses.
• Disconnect the power supply.
• Transport the lift to its new place.
• Install the lift in accordance with chapter 9 “ Installation and Initiation”.
Use new dowels, the used dowels can not be used anymore.
A security check must be performed before reinitiation by a competent
person. Use form “Regular security check”