Operating Manual and Inspection Book
POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT
20100016 OPI
- 53 -
Version 1.1
Hilti injection anchor
POWER LIFT HL 2.30 NT
d
, ,
POWER LIFT HL 2.35 NT
d
, ,
POWER LIFT HL 2.40 NT
e
,
Concrete floor
without floor cover
Anchor
HIT-V-5.8 M10x130
HIT-V-5.8 M12x150
Item no. 387061
HIT-V-5.8 M16x200
Item No. 956437
Drill depth (mm)
h
o
90
108
144
Minimum anchoring depth (mm)
h
ef
90
108
144
Concrete thickness (mm)
H
min
min.120
min.138
min.180
Bore diameter (mm)
d
o
12
14
18
Component thickness (mm)
t
fix
max. 17
max. 19
23
Torque (Nm)
T
inst
20
40
80
Total length (mm)
l
130
150
200
Thread
M
10
12
16
Part count
a
4
b
8
c
10
d
12
e
14
f
16
g
28
Follow the assembly instructions of the anchor manufacturer.
Use longer anchors for floor coverings (screed / tiles).
Similar value injection anchors from other manufacturers (with permission) in compliance with their specifications.
Rights reserved to make
changes!
Cement quality min. C20/25
Normal reinforcement