Operating Manual and Inspection Book
POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT
20100016 OPI
- 37 -
Version 1.1
Check electrical components for function and
condition.
-
Plug
-
Operating lever with button switch
-
During assembly and maintenance always check
the condition of electrical lines. All cables and lines
must be secured so they cannot be crushed, kinked
or contact any moving assembly.
At least 1 x
per year
Daily
Optional energy set:
- Electrical socket
- Pneumatic connection
Check for condition and function.
At least 1 x
per year
Hydraulic hose lines
Storage and duration of use
Excerpt from DIN20066:2002-10
-
For permitted loading, hoses undergo a
natural change. This limits the duration of use.
-
Improper storage, mechanical damage and
unpermitted loads are the most frequent
cause of breakdowns.
-
The duration of use of a hose line including
any storage time should not exceed six years.
Hose lines are to be replaced if/when,
-
Damage to the outer coating up to the insert
(chafe marks, cuts, cracks).
-
The outer coating becomes brittle (crack
formation).
-
Deformation from the natural shape in the
depressurized and pressurized conditions.
-
Leakage.
-
Damage or deformation of the mounting
fixture
-
Meandering of the mounting fixture.
-
The lifetime has been exceeded.
Repair of the hose line using the implemented hose /
mounting fixture is not permitted.
Extending the replacement intervals given in the
guideline is possible if the inspection for safe-work
condition is done in adjusted, shortened time
frames, if required and by competent personnel.
If there is an extension of the replacement interval,
no situation may occur which could result in injury
of employees or other personnel.
Summary of Contents for HL 2.30 NT
Page 2: ......
Page 94: ...Notes ...