OPI-POWER LIFT HF 3S 12000-V1.0-EN
33
Time frame
Maintenance
type position
Person in
charge
Maintenance plan
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Trained ser-
vice personnel
Hydraulic hose lines
Storage and duration of use
Excerpt from DIN20066:2002-10
• For permitted loading, hoses undergo a natural
change. This limits the duration of use.
• Improper storage, mechanical damage and unper-
mitted loads are the most frequent cause of break-
downs.
• The duration of use of a hose line including any stor-
age time should not exceed six years.
Hose lines are to be replaced if/when,
• damage to the outer coating up to the insert (chafe
marks, cuts, cracks)
• the outer coating becomes brittle (crack formation)
• deformation from the natural shape in the depres-
surized and pressurized conditions
• leakage
•
damage or deformation of the mounting fixture
•
meandering of the mounting fixture
•
the lifetime has been exceeded
Repair of the hose line using the implemented hose /
mounting fixture is not permitted.
Extending the replacement intervals given in the
guideline is possible if the inspection for safe-work con-
dition is done in adjusted, shortened time frames, if re-
quired and by competent personnel.
If there is an extension of the replacement interval, no
situation may occur which could result in injury of em-
ployees or other personnel.
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Trained ser-
vice personnel
Excerpt from BGR237:
Specifications for the hydraulic hose lines.
Normal specification:
Recommended exchange intervals:
6 years (operation duration including max. 2 years
storage time).
Increased demands e.g. by
• Increased usage times e.g. multi-shift, short cycle
times and pressure impulses.
•
Increased exterior and interior (due to media) influ
-
ences which significantly reduce the lifetime of the
hose lines.
Recommended exchange intervals:
6 years (operation duration including max. 2 years
storage time)
Summary of Contents for HF 3S 12000
Page 2: ...2 OPI POWER LIFT HF 3S 12000 V1 0 EN ...
Page 4: ......
Page 19: ...OPI POWER LIFT HF 3S 12000 V1 0 EN 19 ...
Page 20: ...20 OPI POWER LIFT HF 3S 12000 V1 0 EN ...
Page 21: ...OPI POWER LIFT HF 3S 12000 V1 0 EN 21 ...
Page 22: ...22 OPI POWER LIFT HF 3S 12000 V1 0 EN ...
Page 53: ...Made in Germany POWER LIFT HF 3S 12000 Made in Germany Spare parts list ...
Page 60: ...60 OPI POWER LIFT HF 3S 12000 V1 0 EN 60 xx Switch box 000STA03600 2 05 07 19 ...