36
OPI-POWER LIFT HF 3S 12000-V1.0-EN
• After setting up the lift columns, lift the cross-con-
nection to the opposite side and fasten it. The hy-
draulic lines are placed in the cross-connection.
• Guide the lines from above into the riser of the
opposite side and connect to the colour marked
positions.
•
Fasten the extension using the long screws (8)
after the tensioning plate (7) has been placed.
8
7
7 Tensioning plate
005
8 Fastening screws
8.1.3
First filling
When filling the hydraulic system, identify already
filled cylinders (with the sticker “first filling” on the
system) and unfilled cylinders (no sticker on the sys
-
tem).
Lifts with this sticker already have hydraulic oil in the
hydraulic cylinders.
First filling with sticker
Required oil volume 9 l (HLP 32).
Lifts with this sticker already have hydraulic oil in the
hydraulic cylinders.
After setting up the electrical connection to the lift,
the hydraulic system can be filled.
9
10
11
9 Operating lever
006
10 Allen key operating lever
11 Oil filling opening
• Loosen and remove the plastic part of the oper-
ating lever (9) of both Allen screws (10).
• Loosen and remove the unit cover.
•
Unscrew the oil filling opening (11).
• Fill with 9 L of hydraulic oil (HLP 32).
•
Raise the lift approx. 1 m by pushing the operating
lever (9).
• The lift rails can be lifted at different times!
• Hang in the lifting arms and secure them (see
8.2).
• Push the operating lever forwards and raise the lift
to its uppermost end position.
Summary of Contents for HF 3S 12000
Page 2: ...2 OPI POWER LIFT HF 3S 12000 V1 0 EN ...
Page 4: ......
Page 19: ...OPI POWER LIFT HF 3S 12000 V1 0 EN 19 ...
Page 20: ...20 OPI POWER LIFT HF 3S 12000 V1 0 EN ...
Page 21: ...OPI POWER LIFT HF 3S 12000 V1 0 EN 21 ...
Page 22: ...22 OPI POWER LIFT HF 3S 12000 V1 0 EN ...
Page 53: ...Made in Germany POWER LIFT HF 3S 12000 Made in Germany Spare parts list ...
Page 60: ...60 OPI POWER LIFT HF 3S 12000 V1 0 EN 60 xx Switch box 000STA03600 2 05 07 19 ...