46
05.04.2011 AD W9002 N
By touching the display area of the imbalance the va-
lues for the left and right correction plane are shown in
1 gram resolution. Touching the area again will switch
back to the initial values.
033
The control run is started by closing
the wheel guard and touching
START.
4.7 Placing weights in mode POS Placing
weights in mode POS
As soon as the wheel is positioned in the „12 o´ clock
position“ (shown by the green arrows) and the gauge
arm is moved from its home position the program „at-
tach wheel weights with the gauge arm“ is activated.
!
If the wheel is not positioned in the 12 o´clock posi-
tion new wheel data are measured as soon as the
gauge arm is moved from its home position and
the imbalance values will no longer be correct for
the wheel.
LEFT CORRECTION PLANE
The wheel is positioned in the „12 o´ clock position“
shown by the green arrows.
034
Place the adhesive wheel weight on the head of the
gauge and remove the adhesive fi lm. With adhesive
weights made of steel the weight is hold on the head by
means of a magnet.
Move the gauge arm from its home position.