Operating Instruction and Documentation
2.30 SL E
- 12 -
5.5 LED - (display visibly) at the operating unit
A position measure system observe the lifting and lowering process. Additional the
functions are made by a visibly display. Find the explanations following:
Operating unit at the column
If following LED s are lighten, means this:
OA1
- LED red - top limit switch is active (master side)
K1 -
LED green - Motor contactor
is active (master side
)
UA1-
LED red
–
below limit switch is active (master side)
OA2
– LED red – top limit switch is active (slave side)
K2
- LED green – Motor contactor is active (slave side)
UA2
– LED red – below limit switch is active (slave side)
Heben
– LED green – the lift is raising
Senken
– LED green – the lift is lowering
Indications at standard function
• raising
up:
the following LED lighten: lifting, K1,K2 - lowering glow
• lowering:
the following LED lighten: lowering, K1,K2 – lifting glow
• top position is reached (top limit switch is active):
the following LED lighten: OA1, OA2, lifting – lowering glow
• lower position is reached (below limit switch is active):
the following LED lighten: UA1, UA2, lowering – lifting glow