Mounting Steps
Hereafter the mounting steps for a Kit L measuring system from NUMERIK JENA will be
described�
• Please read the notes mentioned to the particular mounting steps thorough and follow
the indicated sequence of mounting steps exactly!
• The mounting steps for the Kit L2 and Kit L4 are basically the same�
• Maintain a tightening torque of 1 Nm for all screws!
• Preferably the tape should be mounted in a slot or along an edge�
• Please mark the future location of the scale tape before starting with the mounting�
• The alignment of the scale tape depends on the installation position of the scan head�
•
Ensure that the scanning head‘s scanning fields for the counter and reference tracks are
over the corresponding tracks on the scale tape (see also scheme step 5).
1
Mounting slot
Mounting edge
F = Machine guideway
Accuracy
class
X
±1 µm
0�003
±2 µm
0�006
±3 µm
0�009
±5 µm
0�009
Scale tape
T
SINGLEFLEX
0�5
-0�1
DOUBLEFLEX
0�7
-0�1
!
0.1 0.1
F
X/10
T
0.05
8.1
+0.1
≥8
T
X/10
0.1
0.1
F
30/58
KIT
L
-Series