6.4
Switch-On Behaviour
During power-up procedure of the encoder system the level of power voltage and
signal lines must be below 250 mV.
If the encoder system will be powered-up at a residual voltage between a range of 250 and 400 mV,
internal sensor parameter will not set correctly� This will lead to incorrect encoder signals�
This behaviour has to be observed especially during reset routines of controllers�
Image 11
VCC
V
400 mV
250 mV
sin
cos
Forbidden range during power-up or reset
!
6.3
Electrical Data
Kit L2
Kit L4
Scanning frequency
max� 500 kHz
Supply voltage
5 V ±10%
* with 120 Ω load resistance
Chart 3
Output interfaces
Voltage output
1 V
PP
Square wave output
TTL w/o interpolation, RS 422 with interpolation up to 100-times
Current consumption
Voltage output
≤90 mA*
≤80 mA*
Square wave output
≤220 mA*
≤210 mA*
16/58
KIT
L