background image

Before  any  A/S  Request

Product  Specifications  and  Performance

NM-­5000P

Caution

Ensure  checking  out  the  following  before  applying  for  A/S  if  any  abnormality  occurs  from  the  
product.

The  product  might  fail  to  operate  normally  even  without  any  failure  if  you  use  it  with  no  right  understand-­
ing  on  how  to  use  it.

Checklist  for  any  abnormality  on  the  remote  controller

  Turn  on  the  main  power  switch.

  Check  out  if  the  power  cord  is  accurately  connected.

  Check  out  if  the  fuse  inside  the  main  power  switch  is  disconnected.

  Check  out  if  other  operating  keys  are  pressed  on  the  remote  controller.

  Check  out  if  the  power  cord  is  accurately  connected.

  Connect  the  connector  for  the  remote  controller  again.

Do  not  disassemble  the  product  but  contact  your  nearest  supplier  or  
A/S  center.

Check  out  if  the  connector  for  the  low  frequency  pad  is  connected  accurately.

Checklist  for  operations  of  the  low  frequency  pad

Checklist  for  any  abnormality  on  the  internal  projector

If  various  indicator  lamps  on  the  

remote  controller  are  

not  operating;;

If  the  internal  projector  is  

not  operating;;

If  the  low  frequency  pad  is  

not  operating;;

If  you  see  a  warning  

message  "1E”;;

If  you  see  a  warning  

message  "3E”;;

Product  Specifications  and  Performance

This  product  is  a  medical  device.

It  is  a  safety  message  due  to  failure  in  the  heating  lamp  for  the  internal  
projector.

The  product  will  operate  if  you  replace  the  heating  lamp.
Do  not  disassemble  the  product  but  contact  your  nearest  supplier  or  A/S  center.

It  is  a  safety  message  due  to  failure  in  the  heating  lamp  for  the  external  
projector.

The  product  will  operate  if  you  replace  the  heating  lamp.
Do  not  disassemble  the  product  but  contact  your  nearest  supplier  or  A/S  center.

Combination  Stimulator  NM-­5000P

NUGA  MEDICAL  CO.,LTD.

Dongwha  Medical  Instrument  Complex,  1642-­10,  Dongwha  3-­Ri,  
Munmak-­Eup,  Wonju-­Si,  Gangwon-­Do,  Korea

No.  1478

Manufacturing  License  No.  10-­684

Marked  on  the  product

Main  box:  30kg  (±1.0kg)
Subsidiary  box:  12.5kg  (±1.0kg)
Product  frame  box:  37kg  (±1.0kg)

Main  mat:  565  X  1195  X  170mm  (±10mm)
Sub  mat:  570  X  810  X  150mm  (±10mm)
Product  frame:  1910  X  720  X  560mm  (±10mm)

Refer  to  the  user  manual

Refer  to  the  user  manual

Blood  circulation  improvements,  pain  relief

AC  220V~240V,  50/60Hz

230W

Degree  1  machine  &  BF  type  of  installation

Product  name  and  model  name

Manufacturer

License  number  of  

manufacturing  business

License  number  for  the  

manufacturing  article

Date  of  manufacture  /  

number  of  manufacture

Product  weight  (after  box  packing)

Product  size

Cautions  during  use

Performance  and  using  method

Use  purpose

Electric  rating

Power  consumption

Type  and  degree  of  

protection  for  electric  shocks

Summary of Contents for NM-5000P

Page 1: ...product Before use Please read through cautions for safety in the user manual to use this product safely Product Warranty Enclosed ENGLISH Dongwha Medical Instrument Complex 1642 10 Dongwha 3 Ri Munma...

Page 2: ...WKH FXUUHQW SURGXFW VSHFLILFDWLRQV HWDLOV RQ WKH XVHU PDQXDO PLJKW EH GLIIHUHQW IURP WKRVH RQ WKH SURGXFW 7KH SURGXFW PDQXIDFWXUHU LV DGGLQJ DQG VXSSOHPHQWLQJ QHZ IXQFWLRQV DW DQ WLPH DQG QHZ WHFKQRO...

Page 3: ...ls containing water heavy objects or other objects on the product Otherwise it might cause fire Avoid using any band or belt that does not come as one of components from the purchase of the product Ot...

Page 4: ...roper temperature as there are concerns of burns if the higher temperature is set Any pregnant shall not use the low frequency pad Move the product after separating the power supply from connecting li...

Page 5: ...th a hand which can be stored in a projector pocket nicely during no use Internal Driving Method with Low Noises There are few noises thanks to the minimized friction between the internal projector an...

Page 6: ...ernal projector Projector pocket Introduction Please check out whether all the components are in hand before installing the product Please inquire of your supplier if there is any missing or damaged c...

Page 7: ...ay with Screws for Assembly 4 pieces of Screw No 13 10 pieces of Screw No 8 2 pieces of Screw No 12 5 pieces of Screw No 7 2 pieces of buffer rubber 7 pieces of Screw No 4 1 piece of L wrench 9 pieces...

Page 8: ...on between the internal projector and rail due to the specially designed guard rail which can be used semi permanently by minimizing the driving load Product frame Internal projector External projecto...

Page 9: ...External Projector Button to turn on off the power supply for the external projector Power Button for Low Frequency Pad Button to turn on off the power supply for the low frequency pad Temperature Co...

Page 10: ...Prohibit any pregnant woman near the parturition patients with rachischisis patients wearing a cardiac pacemaker and or patients with severe heart diseases from using the product Otherwise it is like...

Page 11: ...rame with 4 pieces of Screw No 16 to the assembled frame leg as shown in the picture Insert both the center support and leg support Insert a piece of center support into the assembled molding frame wi...

Page 12: ...eg and leg support with 2 pieces of Screw No 13 as shown in the picture Place the sub angle frame Put the sub angle frame on the assembled product frame Loosen screws placed on the sub angle frame and...

Page 13: ...n the product Turn on the power switch after the power supply cord is connected to the power input on the side of the main mat Set temperature to the sub heater Turn the dialer to set the desired temp...

Page 14: ...the desired temperature in the sub heater attached to the side of the sub mat Use the product Lay yourself down with your legs toward the sub mat and press the Auto button in the remote controller for...

Page 15: ...de 1 Press the Auto button to operate the internal projector No separate operation is necessary in the middle as the product stops automatically after operations The product automatically stops after...

Page 16: ...duct automatically stops after round trip massage operations between the central thoracic vertebrae and vertebrae lumbales for about 38 minutes Auto Mode Massage function between the thoracic vertebra...

Page 17: ...Temperature setting per 2 TEMP PJT LOW FREQ PJT L F Min Max CONT TEMP PJT LOW FREQ PJT L F Min Max CONT Manual Mode Manual Mode Use the product after placing the internal projector at the desired pos...

Page 18: ...he belly before wearing the low frequency pad if there is no gel at home Use a piece of towel or cloth after squeezing it out completely to prevent it from flowing water when it is wetted with water C...

Page 19: ...th one person on the product and another person with the external projector while sitting 6WHSZLVH FRQWURO E FDQ EH GRQH ZLWK RU LI WKH PDW DQJOH LV set upward Grab the product frame at the mat bottom...

Page 20: ...ed position to set temperature 40 65 Turn the dial to OFF after use to turn off the power supply Otherwise it might cause failure How to Store and Clean the Product after Use Check Indicator Window of...

Page 21: ...tion Do not disassemble the product arbitrarily if any error occurs but remove the power plug turn off the power switch and then contact your supplier I RX GLVDVVHPEOH WKH SURGXFW DUELWUDULO LW PLJKW...

Page 22: ...indicator window on the remote controller turned off 2 Is the operating lamp on the remote controller turned off 3 Is the power lamp on the projector turned off 4 Is the power switch turned off to th...

Page 23: ...d Performance This product is a medical device It is a safety message due to failure in the heating lamp for the internal projector The product will operate if you replace the heating lamp Do not disa...

Page 24: ...MEMO NM 5000P...