Equitrac Professional TouchPoint Console Installation and Setup Guide
27
Chapter 3: Initial Local Configuration
CAUTION:
The TPC Application version 2.1.x.x must only be used with the corresponding Platform Firmware version
2.0.12 or later, whereas Application 1.x.x.x (1.0.17.15 and higher) must only be used with Platform version 1.0.36.
Update the firmware
1
On the server hosting the Equitrac Professional Core Accounting Server, open Windows Explorer and navigate to
Program Files > Equitrac > Professional > Tools
and open the
EQTerminalUpdate.exe
tool.
2
Add the TPC(s) to update:
a
In the
Terminal Device List
group box, click
Add
. An
Add device
dialog opens.
b
In the
Device IP addres
s field, enter the IP address of the TPC you want to update, then click
OK
. The TPC
appears in the Terminal device list matrix.
3
From the
Filter by device type
drop-down list, choose
TouchPoint Console
, then press
Refresh
.
4
Under
Advanced option
s, ensure
Automatically restart after device is updated
is
unchecked
.
EP 5.3.0
2.1.1.57
2.0.12
1.1.1.112 or
1.1.3.87
1.0.36
EP 5.3.1
2.1.3.59
2.0.12
1.1.3.87
1.0.36
EP 5.3.1 +HF-
178625-DCE or
greater
2.1.4.67
2.0.12
1.1.4.15
1.0.36
EP 5.4.0
2.1.4.67
2.0.12
1.1.4.15
1.0.36
2.x Release