NTI VEEMUX AUDIO VIDEO MATRIX SWITCH VIA CAT5
16
The Mode parameter will let you select between a manual IP setting and a DHCP assigned dynamic IP address setting. An
asterisk indicates which mode is configured, an arrow shows which mode is being selected. To change the configured setting and
move the asterisk, select the desired mode and press the
Enter
button.
If you choose a manual IP setting, the IP parameter provides the fields for entering a valid IP address. Use the up and down
arrows to advance the numbers, and the
Enter
button to move from field to field. Press
List
to exit this screen.
Selections 3, 4 are necessary to apply valid values for your Subnet Mask and Gateway. Navigate these settings as described for
setting the IP address.
3. Under the “DDC” menu are two parameters:
1- Chose Input
(Choose Input)
2- All Inputs
You can either 1) select the EDID information source for each input individually, or 2) for all inputs at once. Within this section
you will need to select between:
default 1-
the
inputs will get EDID information from a predefined table in the VEEMUX supporting CPU monitors
local DDC-
the
inputs will get EDID information from local extender port
From Out (?)-
select which Output port the Input will get EDID information from regardless of which output it is
connected to
Mix DDC-
collect EDID information from all remote ports and finds the parameter common to all. If no common
parameter is found, it uses the information found at the remote connected to port 1.
4. The fourth option in the main menu is ”Standby”. If you select Standby, the VEEMUX switch will immediately go into a power
saver mode and the LCD display will go blank. It will remain in this state until
1) any button is pressed on the front panel,
2) the Standby button is pressed on the optional IR Remote Control (page
50
), or
3) the “Disable Standby” button is pressed in the web interface (page
46
)
Save and Load (Recall) Config
The VEEMUX provides the ability to save and recall up to 100 switch configurations using the LCD menu. The switch
configurations define the current port connections, volume control settings, and video blank status.
Note: The IRT-UNV IR Remote (page 49) can also be used to access these configurations by using the “SAVE” and
“RECALL” buttons.
To save a configuration, select “Save Config” from the main menu followed by a numeric button(s) (0-99) corresponding to
the memory slot the configuration is to be saved in. Press
Enter
after your selection to force the current configuration to
immediately be saved to the selected memory slot.
Note: Memory slot 0 is the default configuration. The VEEMUX will boot up to whatever is saved as configuration 0.
Configurations can be loaded (recalled) in much the same manner. To recall, select “Load Config” from the main menu
followed by the numeric button(s) (0-99) corresponding to the memory slot from which the configuration is to be recalled. Press
Enter
after your selection to immediately force the switch to change the current switch configuration to match that of the
configuration recalled.